3–29

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

SYS

Word

Bit

Description

SYS04

Watchdog Time-Out Status

B00

= 0 Normal
= 1 First Clamp Close Profile Watchdog Time-Out
The module sets this bit when the time required for the profile equals or exceeds the Watchdog Timer preset (FCC08).
The module resets this bit when:

S

it completes the profile, or

S

it receives a new action execution command that terminates the profile

The module does not leave this bit set when holding its outputs to FCC33 - FCC40 at completion of this profile.

B01

= 0 Normal
= 1 Second Clamp Close Profile Watchdog Time-Out
The module sets this bit when the time required for the profile equals or exceeds the Watchdog Timer preset (SCC08).
The module resets this bit when:

S

it completes the profile, or

S

it receives a new action execution command that terminates the profile

The module does not leave this bit set when holding its outputs to SCC33 - SCC40 at completion of this profile.

B02

= 0 Normal
= 1 Third Clamp Close Profile Watchdog Time-Out
The module sets this bit when the time required for the profile equals or exceeds the Watchdog Timer preset (TCC08).
The module resets this bit when:

S

it completes the profile, or

S

it receives a new action execution command that terminates the profile

The module does not leave this bit set when holding its outputs to TCC33 - TCC40 at completion of this profile.

B03

= 0 Normal
= 1 Clamp Low Pressure Close Profile Watchdog Time-Out
The module sets this bit when the time required for the profile equals or exceeds the Watchdog Timer preset (LPC08).
The module resets this bit when:

S

it completes the profile, or

S

it receives a new action execution command that terminates the profile

The module does not leave this bit set when holding its outputs to LPC33 - LPC40 at completion of this profile.

B04-B06

Open

B07

= 0 Normal
= 1 Pre-decompression Movement Watchdog Time-Out
Module sets this bit when the time required for the movement equals or exceeds the Watchdog Timer preset (PRC08).
The module resets this bit when:

S

it completes the movement, or

S

it receives a new action execution command that terminates the movement

The module does not leave this bit set when holding its outputs to PRC33 - PRC40 at completion of this movement.

B08

= 0 Normal
= 1 Plastication Profile Watchdog Time-Out
The module sets this bit when the time required for the profile equals or exceeds the Watchdog Timer preset (PLC08).
The module resets this bit when:

S

it completes the profile, or

S

it receives a new action execution command that terminates the profile

The module does not leave this bit set when holding its outputs to PLC33 - PLC40 at completion of this profile.

B09

= 0 Normal
= 1 Post-decompression Movement Watchdog Time-Out
The module sets this bit when the time required for the movement equals or exceeds the Watchdog Timer preset
(PSC08). The module resets this bit when:

S

it completes the movement, or

S

it receives a new action execution command that terminates the movement

The module does not leave this bit set when holding its outputs to PSC33 - PSC40 at completion of this movement.

B10

= 0 Normal
= 1 First Clamp Open Profile Watchdog Time-Out
The module sets this bit when the time required for the profile equals or exceeds the Watchdog Timer preset (FOC08).
The module resets this bit when:

S

it completes the profile, or

S

it receives a new action execution command that terminates the profile.

The module does not leave this bit set when holding its outputs to FOC33 - FOC40 at completion of this profile.