Id = 17 – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 263

Advertising
background image

4–39

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 16

0240

PSC40 is out of range. Valid range is 00000

≤

PSC40

≤

09999

0405

PSC05 is out of range.
if:

then:

MCC13 and MCC14

PSC05 must be within 00000

≤

PSC05

≤

MCC14 – MCC13

are both non-zero

MCC13 is non-zero and

PSC05 must be within 00000

≤

PSC05

≤

MCC10 – MCC13

MCC14 is zero

MCC13 is zero and

PSC05 must be within 00000

≤

PSC05

≤

MCC14 – MCC09

MCC14 is non-zero

MCC13 and MCC14

PSC05 must be within 00000

≤

PSC05

≤

MCC10 – MCC09

are both zero

0457

PSC57 is out of range.
If non-zero, PSC57 must be within MCC17 < PSC57

≤

MCC18

0905

PSC05 is too large.
if:

then:

MCC13 and MCC14

PSC05 must be within MCC13 + PPC61 + PPC62 + PSC05

are both non-zero

≤

MCC14

MCC13 is zero and

PSC05 must be within MCC09 + PPC61 + PPC62 + PSC05

MCC14 is non-zero

≤

MCC14

MCC13 is non-zero and

PSC05 must be within MCC13 + PPC61 + PPC62 + PSC05

MCC14 is zero

≤

MCC10

MCC13 and MCC14

PSC05 must be within MCC09 + PPC61 + PPC62 + PSC05

are both zero

≤

MCC10

ID = 17

FOC – First Clamp Open Configuration Block

Error Code

Description

ID = 17

0205

FOC05 is out of range. Valid range is 00000

≤

FOC05

≤

09999

0206

FOC06 is out of range. Valid range is 00000

≤

FOC06

≤

09999

0208

FOC08 is out of range. Valid range is 00000

≤

FOC08

≤

09999

0209

FOC09 is out of range. Valid range is 00000

≤

FOC09

≤

09999

0210

FOC10 is out of range. Valid range is 00000

≤

FOC10

≤

09999

0211

FOC11 is out of range. Valid range is 00000

≤

FOC11

≤

09999

0212

FOC12 is out of range. Valid range is 00000

≤

FOC12

≤

09999

0213

FOC13 is out of range. Valid range is 00000

≤

FOC13

≤

09999

0214

FOC14 is out of range. Valid range is 00000

≤

FOC14

≤

09999

0215

FOC15 is out of range. Valid range is 00000

≤

FOC15

≤

09999

0216

FOC16 is out of range. Valid range is 00000

≤

FOC16

≤

09999

0217

FOC17 is out of range. Valid range is 00000

≤

FOC17

≤

09999

0218

FOC18 is out of range. Valid range is 00000

≤

FOC18

≤

09999

0219

FOC19 is out of range. Valid range is 00000

≤

FOC19

≤

09999

0220

FOC20 is out of range. Valid range is 00000

≤

FOC20

≤

09999

0221

FOC21 is out of range. Valid range is 00000

≤

FOC21

≤

09999

0222

FOC22 is out of range. Valid range is 00000

≤

FOC22

≤

09999

0223

FOC23 is out of range. Valid range is 00000

≤

FOC23

≤

09999

0224

FOC24 is out of range. Valid range is 00000

≤

FOC24

≤

09999

0225

FOC25 is out of range. Valid range is 00000

≤

FOC25

≤

09999

0226

FOC26 is out of range. Valid range is 00000

≤

FOC26

≤

09999

0227

FOC27 is out of range. Valid range is 00000

≤

FOC27

≤

09999

Advertising