Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

LPC

Bit-mapped Control Words

Word

Bit

Description

LPC01

Block ID = 00000110 (Low byte). High byte reserved for the module. Do not use.

LPC02

Configuration Selections

B00-B03

Open

B04-B06

Selected Pressure Control Valve
the module uses its algorithm to drive the following output during any Clamp Low Pressure Close Profile.
B06 B05 B04
0 0 0 Output #1
0 0 1 Output #2
0 1 0 Output #3
0 1 1 Output #4
1 0 0 Output #5
1 0 1 Output #6
1 1 0 Output #7
1 1 1 Output #8

B07

Pressure Algorithm Selection
= 0 Dependent Gains (ISA)
= 1 Independent Gains (A-B)

B08 - B15

Open

LPC03 - 05

Open

Expert Response Compensation (ERC) Percentage

Word

Description

LPC06

Minimum Pressure Control ERC Percentage [31]
Although error coding allows range of 00000 to 09999, the module limits it to a minimum of 01000.

Watchdog Timers

Word

Description

LPC07

Tonnage Watchdog Timer Preset [21]

When the module completes the Clamp Low Pressure Close Profile and sets its outputs to LPC33 - LPC40, it:

S

starts an internal Tonnage Watchdog timer

S

stops this timer when it sets master status bit SYS03-B02 and reports the accumulated value of the timer in SYS57

S

stops this timer when it sets master status bit SYS03-B02 and reports the accumulated value of the timer in SYS57

S

resets SYS57 to zero when it detects an F-to-T transition of DYC03-B00

S

sets master status bit SYS04-B15 when SYS57 equals or exceeds this entry

A zero entry inhibits SYS04-B15.

LPC08

Profile Watchdog Timer Preset [21]

When the module starts the Clamp Low Pressure Close Profile, it:

S

starts an internal Profile Watchdog timer

S

stops this timer and resets its accumulated value to zero (after reporting total execution time in CPS60) when it completes the

S

stops this timer and resets its accumulated value to zero (after reporting total execution time in CPS60) when it completes the

profile

S

sets master status bit SYS04-B03 when the accumulated value of this timer equals or exceeds this entry

A zero entry inhibits SYS04-B03.

Unselected Valve Set-output Values

When the module starts the Clamp Low Pressure Close Profile, it:

sets its unselected outputs to the values listed below

ignores the unselected value of the selected output

uses ramp rates LPC17 - LPC32 to ramp unselected outputs

LPC – Clamp Low Pressure
Close Configuration Block