2–16

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

DYC02

B02

if:

then the module:

If clamp position exceeds CPC61

and all within any box are true:

then the module:

– CPC29 is not zero
– clamp position exceeds a non-zero entry in CPC29, CPC32, or CPC35

terminates any action in progress and
starts Third Clamp Close Profile (see note)

– CPC29 is zero or is not zero when clamp position is less than all

non-zero entries in CPC29, CPC32, and CPC35

– CPC03-B10 is SET

terminates any action in progress and
sets outputs to TCC33 - TCC40 (see note)

– CPC29 is zero or is not zero when clamp position is less than all

non-zero entries in CPC29, CPC32, and CPC35

– CPC03-B10 is RESET
Also occurs when clamp position exceeds CPC62 but not CPC61.

terminates any action in progress and
starts Low Pressure Clamp Close Profile
(see note)

clamp position equals or is less than CPC62

terminates any action in progress and
sets outputs to LPC33 - LPC40 (see note)

Note: If ejector position exceeds EPC63, the module ceases all action execution,

sets its outputs to zero, and sets alarm status bit SYS14-B08.

B03

= 0 Normal
= 1 Execute Low Pressure Clamp Close Profile
A false-to-true transition of this bit forces the module to do

one of the following, attempted in the order listed.

if:

then the module:

any of SYS07-B00 through B05 are SET

ignores any profile commands

ejector position exceeds EPC63

latches alarm status bit SYS14-B08

SYS15-B06 is RESET

latches SYS13-B04

If all within any bo

x are true:

then the module:

– CPC38 is not zero
– clamp position exceeds CPC38
Also occurs if clamp position exceeds CPC62 but not CPC61.

terminates any action in progress and
starts Low Pressure Clamp Close Profile
(see note)

clamp position equals or is less than CPC62

terminates any action in progress and
sets outputs to LPC33 - LPC40 (see note)

Note: If ejector position exceeds EPC63, the module ceases all action execution,

sets its outputs to zero, and sets alarm status bit SYS14-B08.

Ram (Screw) Profiles Execution Commands
Bits DYC02-B04 - DYC02-B09 are the six

action execution commands available to initiate all profiled ram (screw) movements

(including both decompression movements). You may logically link all six in a single integrated machine movement if all three
Logical Bridge Bits are RESET. These three bits are:
HPC03-B08 - Link Inj/Pack/Hold and Pre-decompress (Inj/Pack/Hold always linked)
HPC03-B09 - Link Pre-decompress and Plastication
PPC03-B08 - Link Plastication and Post-decompress
If all three of these bits are RESET, transfer only DYC02-B04 to the module to force the entire Ram (Screw) portion of an
automatic machine cycle.

B04

= 0 Normal
= 1 Execute Injection Profile
A false-to-true transition of this bit forces the module to do

one of the following, attempted in the order listed.

if:

then the module:

any of SYS07-B00 through B05 are SET

ignores any profile commands

SYS15-B08 is RESET

latches SYS13-B05

either of the following are true:
– ram (screw) position exceeds non-zero IPC61
– IPC61 is zero

terminates any action in progress and
starts the Injection Profile

both of the following are true:
– ram (screw) position equals or is less than non-zero IPC61
– HPC11 is not zero

terminates any action in progress and
starts the Pack Profile

both of the following are true:
– ram (screw) position equals or is less than non-zero IPC61
– HPC11 is zero

terminates any action in progress and
starts the Hold Profile