Hpc - pack/hold profile block, Hpc – pack/hold profile block – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 116

Advertising
background image

2–50

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Profile Tuning Constants

Word

Description

HDC49

Proportional Gain for Ram Press Control [30]

HDC50

Integral Gain for Ram Press Control [27] or [28]

HDC51

Derivative Gain for Ram Press Control [26] or [21]

HDC52

Proportional Gain for Cav Press Control [30]

HDC53

Integral Gain for Cav Press Control [27] or [28]

HDC54

Derivative Gain for Cav Press Control [26] or [21]

HDC55 - 56 Open

Profile Pressure Alarm Setpoint

Word

Description

HDC57

Profile High Ram (Screw) Pressure Alarm Setpoint [01] The module compares real-time ram (screw) pressure against this entry
when executing the Hold Profile. The module sets alarm status bit SYS06-B04 when ram (screw) pressure equals or exceeds this
entry during the Hold Profile. A zero entry inhibits SYS06-B04.

HDC58

Profile High Cavity Pressure Alarm Setpoint [04] The module compares real-time cavity pressure against this entry when executing
the Hold Profile. The module sets alarm status bit SYS06-B05 when cavity pressure equals or exceeds this entry during the Hold
Profile. A zero entry inhibits SYS06-B05.

HDC59 - 64 Open

Bit-mapped Control Words

Word

Bit

Description

HPC01

Block ID = 00001100 (Low byte). High byte reserved for the module. Do not use.

HPC02

Open

HPC03

Configuration Selections

Profile Algorithm Selections

B00

= 0 Ram Press/Time selected for Pack Profile
= 1 Cav Press/Time selected for Pack Profile

B01

Open

B02

= 0 Ram Press/Time selected for Hold Profile
= 1 Cav Press/Time selected for Hold Profile

B03-B07

Open

B08

Hold/Pre-decompression Logical Bridge Selection
= 0 Start Pre-decompression Movement at End of Hold Profile
= 1 Stop and Set-output at End of Hold Profile
The module checks the state of this pause bit upon completion of Hold Profile to determine what further action to take:
if:

then the module:

SET

sets its outputs to HDC33 - HDC40

RESET, SYS15-B12 = 1,

immediately begins the Pre-decompression Movement

and PRC05 > 00000

RESET, SYS15-B12 = 1,

reacts as if it had just completed the Pre-decompression Movement and continues

and PRC05 = 00000

operation based on the state of HPC03-B09

RESET, SYS15-B12 = 0,

reacts as if it had just received an F-to-T transition of DYC02-B08

and HPC03-B09 = 0

RESET, SYS15-B12 = 0,

sets its outputs to zero and latches SYS13-B08

and HPC03-B09 = 1

HPC – Pack/Hold Profile Block

Advertising