Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 95

Advertising
background image

2–29

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

EAC

Pressure Control Limits

Word

Description

EAC41

Advance stroke Pressure Minimum Control Limit [03] Minimum controllable ejector-advance pressure attainable during any Press/
Pos Ejector Profile advance stroke. The module expects this ejector-advance pressure when setting its selected pressure advance
valve to the %- output in EAC43.

EAC42

Advance stroke Pressure Maximum Control Limit [03] Maximum controllable ejector-advance pressure attainable during any Press/
Pos Ejector Profile advance stroke. The module expects this ejector-advance pressure when setting its selected pressure advance
valve to the %- output in EAC44.

EAC43

Selected Pressure Advance Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected
pressure advance valve during any Press/Pos Ejector Profile. The module expects a pressure equal to EAC41 when setting the
selected pressure advance valve to this %-output during stroke execution. The Press/Pos Ejector Profile advance stroke will be
executed as a reverse-acting algorithm if this entry is greater than EAC44.

EAC44

Selected Pressure Advance Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected
pressure advance valve during any Press/Pos Ejector Profile. The module expects a pressure equal to EAC42 when setting the
selected pressure advance valve to this %-output during stroke execution. The Press/Pos Ejector Profile advance stroke will be
executed as a reverse-acting algorithm if this entry is less than EAC43.

Velocity Control Limits

Word

Description

EAC45

Advance stroke Velocity Minimum Control Limit [10] Minimum controllable ejector-advance velocity attainable during any Vel/Pos
Ejector Profile advance stroke. The module expects this ejector-advance velocity when setting its selected velocity-advance valve to
the %-output in EAC47.

EAC46

Advance stroke Velocity Maximum Control Limit [10] Maximum controllable ejector-advance velocity attainable during any Vel/Pos
Ejector Profile advance stroke. The module expects this ejector-advance velocity when setting its selected velocity-advance valve to
the %-output in EAC48.

EAC47

Selected Velocity Advance Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected
velocity advance valve during any Vel/Pos Ejector Profile. The module expects a velocity equal to EAC45 when setting the selected
velocity advance valve to this %-output during stroke execution. The Vel/Pos Ejector Profile advance stroke will be executed as a
reverse-acting algorithm if this entry is greater than EAC48.

EAC48

Selected Velocity Advance Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected
velocity advance valve during any Vel/Pos Ejector Profile. The module expects a velocity equal to EAC46 when setting the selected
velocity advance valve to this %-output during stroke execution. The Vel/Pos Ejector Profile advance stroke will be executed as a
reverse-acting algorithm if this entry is less than EAC47.

Advance Stroke Tuning Constants

Word

Description

EAC49

Proportional Gain for Pressure Control [30]

EAC50

Integral Gain for Pressure Control [27] or [28]

EAC51

Derivative Gain for Pressure Control [26] or [21]

EAC52

Proportional Gain for Velocity Control [28]

EAC53

Feed Forward Gain for Velocity Control [30]

EAC54 - 56

Open

Profile Pressure Alarm Setpoint

Word

Description

EAC57

Profile High Pressure Alarm Setpoint [03] The module compares real-time ejector pressure against this entry when executing the
Ejector Profile. The module sets alarm status bit SYS06-B13 when ejector pressure equals or exceeds this entry during the Ejector
Profile. A zero entry inhibits SYS06-B13.

EAC58 - 64

Open