4–29

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 12

0438

HPC38 is out of range.
If non-zero, HPC38 must be within HDC45

HPC38

HDC46

0439

HPC39 is out of range.
If non-zero, HPC39 must be within HDC41

HPC39

HDC42

0441

HPC41 is out of range. Valid range is 00000

HPC41

HDC46

0442

HPC42 is out of range. Valid range is 00000

HPC42

HDC42

0503

You have selected CavPress/Time execution for the Pack Profile by HPC03-B00 = 1; how-
ever, your bit pattern in MCC02 indicates that your QDC module is not configured for con-
nection of a cavity pressure sensor.

0504

You have selected closed-loop RamPress/Time execution for the Pack Profile by
HPC04-B00 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC
module does not have access to a connected ram (screw) pressure transducer.

0507

You have selected CavPress/Time execution for the Hold Profile by HPC03-B02 = 1; how-
ever, your bit pattern in MCC02 indicates that your QDC module is not configured for con-
nection of a cavity pressure sensor.

0508

You have selected closed-loop CavPress/Time execution for the Pack Profile by
HPC04-B01 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC
module does not have access to a connected cavity pressure transducer.

0512

You have selected closed-loop RamPress/Time execution for the Hold Profile by
HPC04-B02 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC
module does not have access to a connected ram (screw) pressure transducer.

0516

You have selected closed-loop CavPress/Time execution for the Hold Profile by
HPC04-B03 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC
module does not have access to a connected cavity pressure transducer.

0600

Your entire Pack/Hold Profile Command Block has been rejected because the QDC module
does not have a valid Hold Configuration Command Block on-board (SYS15-B10 = 0).

0609

Your HPC09 must be zero because PKC is invalid (SYS15-B09 = 0).

0610

Your HPC10 must be zero because PKC is invalid (SYS15-B09 = 0).

0611

Your HPC11 must be zero because PKC is invalid (SYS15-B09 = 0).

0612

Your HPC12 must be zero because PKC is invalid (SYS15-B09 = 0).

0613

Your HPC13 must be zero because PKC is invalid (SYS15-B09 = 0).

0614

Your HPC14 must be zero because PKC is invalid (SYS15-B09 = 0).

0615

Your HPC15 must be zero because PKC is invalid (SYS15-B09 = 0).

0616

Your HPC16 must be zero because PKC is invalid (SYS15-B09 = 0).

0617

Your HPC17 must be zero because PKC is invalid (SYS15-B09 = 0).

0618

Your HPC18 must be zero because PKC is invalid (SYS15-B09 = 0).

0619

Your HPC19 must be zero because PKC is invalid (SYS15-B09 = 0).

0620

Your HPC20 must be zero because PKC is invalid (SYS15-B09 = 0).

0621

Your HPC21 must be zero because PKC is invalid (SYS15-B09 = 0).

0622

Your HPC22 must be zero because PKC is invalid (SYS15-B09 = 0).

0623

Your HPC23 must be zero because PKC is invalid (SYS15-B09 = 0).

0624

Your HPC24 must be zero because PKC is invalid (SYS15-B09 = 0).

0625

Your HPC25 must be zero because PKC is invalid (SYS15-B09 = 0).

0711

HPC11 cannot be 00000 because HPC14 > 00000.

0714

HPC14 cannot be 00000 because HPC17 > 00000.

0717

HPC17 cannot be 00000 because HPC20 > 00000.

0720

HPC20 cannot be 00000 because HPC23 > 00000.

0728

HPC28 cannot be 00000.

0731

HPC31 cannot be 00000 because HPC34 > 00000.

0734

HPC34 cannot be 00000 because HPC37 > 00000.

0737

HPC37 cannot be 00000 because HPC40 > 00000.

0809

HPC09 must be 00000 when HPC11 = 00000.