Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 108

Advertising
background image

2–42

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Output Ramp Rates

The module uses the following ramp rates when moving its outputs
from setpoint to setpoint during the First Clamp Close Profile. The
module interprets a ramp rate entry of zero as a step function ramp
(ramp disable).

Word

Description

FCC17

Output #1 Acceleration Ramp Rate during Profile [20]

FCC18

Output #2 Acceleration Ramp Rate during Profile [20]

FCC19

Output #3 Acceleration Ramp Rate during Profile [20]

FCC20

Output #4 Acceleration Ramp Rate during Profile [20]

FCC21

Output #5 Acceleration Ramp Rate during Profile [20]

FCC22

Output #6 Acceleration Ramp Rate during Profile [20]

FCC23

Output #7 Acceleration Ramp Rate during Profile [20]

FCC24

Output #8 Acceleration Ramp Rate during Profile [20]

FCC25

Output #1 Deceleration Ramp Rate during Profile [20]

FCC26

Output #2 Deceleration Ramp Rate during Profile [20]

FCC27

Output #3 Deceleration Ramp Rate during Profile [20]

FCC28

Output #4 Deceleration Ramp Rate during Profile [20]

FCC29

Output #5 Deceleration Ramp Rate during Profile [20]

FCC30

Output #6 Deceleration Ramp Rate during Profile [20]

FCC31

Output #7 Deceleration Ramp Rate during Profile [20]

FCC32

Output #8 Deceleration Ramp Rate during Profile [20]

End of Profile Set-output Values

When the module completes the First Clamp Close Profile and
CPC03-B08 is SET, it:

sets its outputs to the following values

sets status bit SYS22-B00

uses ramp rates FCC17 - FCC32 when changing outputs to these
values

Use these values for setting cores if applied before starting the
Second Clamp Close Profile.

Word

Description

FCC33

Output #1 Set-output Value at End of Profile [19]

FCC34

Output #2 Set-output Value at End of Profile [19]

FCC35

Output #3 Set-output Value at End of Profile [19]

FCC36

Output #4 Set-output Value at End of Profile [19]

FCC37

Output #5 Set-output Value at End of Profile [19]

FCC38

Output #6 Set-output Value at End of Profile [19]

FCC39

Output #7 Set-output Value at End of Profile [19]

FCC40

Output #8 Set-output Value at End of Profile [19]