Erc - ejector retract configuration block, Erc – ejector retract configuration block – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 103

Advertising
background image

2–37

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

ERC

Bit-mapped Control Words

Word

Bit

Description

ERC01

Block ID = 00010111 (Low byte). High byte reserved for the module. Do not use.

ERC02

Configuration Selections

B00-B02

Selected Velocity Retract Control Valve The module uses its algorithm to drive the following output during any retract
stroke (Vel/Pos Ejector Profile).
B02 B01 B00
0 0 0 Output #1
0 0 1 Output #2
0 1 0 Output #3
0 1 1 Output #4
1 0 0 Output #5
1 0 1 Output #6
1 1 0 Output #7
1 1 1 Output #8

B03

Open

B04-B06

Selected Pressure Retract Control Valve The module uses its algorithm to drive the following output during any retract
stroke (Press/Pos Ejector Profile).
B06 B05 B04
0 0 0 Output #1
0 0 1 Output #2
0 1 0 Output #3
0 1 1 Output #4
1 0 0 Output #5
1 0 1 Output #6
1 1 0 Output #7
1 1 1 Output #8

B07

Pressure Algorithm Selection
= 0 Dependent Gains (ISA)
= 1 Independent Gains (A-B)

B08-B15

Open

ERC03 -04

Open

Expert Response Compensation (ERC) Percentage

Word

Description

ERC05

Minimum Velocity-retract Control ERC Percentage [31] Although error coding allows this entry to be within the range of 00000 to
09999, the module limits it to a minimum of 01000.

ERC06

Minimum Pressure-retract Control ERC Percentage [31] Although error coding allows this entry to be within the range of 00000 to
09999, the module limits it to a minimum of 01000.

ERC07, 08

Open

Unselected Valve Set-output Values

When the module starts an Ejector Profile retract stroke, it:

sets its unselected outputs to the values listed below

ignores the unselected value of the selected output

uses ramp rates ERC17 - ERC32 to ramp unselected outputs

ERC – Ejector Retract
Configuration Block

Advertising