Id = 11 – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 250

Advertising
background image

4–26

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 10

0243

PKC43 is out of range. Valid range is 00000

≤

PKC43

≤

09999

0244

PKC44 is out of range. Valid range is 00000

≤

PKC44

≤

09999

0247

PKC47 is out of range. Valid range is 00000

≤

PKC47

≤

09999

0248

PKC48 is out of range. Valid range is 00000

≤

PKC48

≤

09999

0249

PKC49 is out of range. Valid range is 00000

≤

PKC49

≤

09999

0250

PKC50 is out of range. Valid range is 00000

≤

PKC50

≤

09999

0251

PKC51 is out of range. Valid range is 00000

≤

PKC51

≤

09999

0252

PKC52 is out of range. Valid range is 00000

≤

PKC52

≤

09999

0253

PKC53 is out of range. Valid range is 00000

≤

PKC53

≤

09999

0254

PKC54 is out of range. Valid range is 00000

≤

PKC54

≤

09999

0343

PKC43 is equal to PKC44. They must not be equal.

0347

PKC47 is equal to PKC48. They must not be equal.

0441

PKC41 is out of range. Valid range is 00000

≤

PKC41 < PKC42

0442

PKC42 is out of range. Valid range is PKC41 < PKC42

≤

09999

0445

PKC45 is out of range. Valid range is 00000

≤

PKC45 < PKC46

0446

PKC46 is out of range. Valid range is PKC45 < PKC46

≤

20000

0457

PKC57 is out of range.
If non-zero, PKC57 must be within MCC17 < PKC57

≤

MCC18

0458

PKC58 is out of range.
If non-zero, PKC58 must be within MCC57 < PKC58

≤

MCC58

0502

Your bit pattern in PKC02-B02, PKC02-B01, and PKC02-B00 indicates a selected cavity
pressure control valve that is unconnected according to your entries in MCC02 and MCC04.

0506

Your bit pattern in PKC02-B06, PKC02-B05, and PKC02-B04 indicates a selected ram
(screw) pressure control valve that is unconnected according to your entries in MCC02 and
MCC04.

ID = 11

HDC – Hold Configuration Block

Error Code

Description

ID = 11

0205

HDC05 is out of range. Valid range is 00000

≤

HDC05

≤

09999

0206

HDC06 is out of range. Valid range is 00000

≤

HDC06

≤

09999

0209

HDC09 is out of range. Valid range is 00000

≤

HDC09

≤

09999

0210

HDC10 is out of range. Valid range is 00000

≤

HDC10

≤

09999

0211

HDC11 is out of range. Valid range is 00000

≤

HDC11

≤

09999

0212

HDC12 is out of range. Valid range is 00000

≤

HDC12

≤

09999

0213

HDC13 is out of range. Valid range is 00000

≤

HDC13

≤

09999

0214

HDC14 is out of range. Valid range is 00000

≤

HDC14

≤

09999

0215

HDC15 is out of range. Valid range is 00000

≤

HDC15

≤

09999

0216

HDC16 is out of range. Valid range is 00000

≤

HDC16

≤

09999

0217

HDC17 is out of range. Valid range is 00000

≤

HDC17

≤

09999

0218

HDC18 is out of range. Valid range is 00000

≤

HDC18

≤

09999

0219

HDC19 is out of range. Valid range is 00000

≤

HDC19

≤

09999

0220

HDC20 is out of range. Valid range is 00000

≤

HDC20

≤

09999

0221

HDC21 is out of range. Valid range is 00000

≤

HDC21

≤

09999

0222

HDC22 is out of range. Valid range is 00000

≤

HDC22

≤

09999

0223

HDC23 is out of range. Valid range is 00000

≤

HDC23

≤

09999

0224

HDC24 is out of range. Valid range is 00000

≤

HDC24

≤

09999

Advertising