Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 247

Advertising
background image

4–23

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 9

0461

Your non-zero entry for IPC61 is out of range.
if:

then:

MCC13 and MCC14

IPC61 must be within 00000

IPC61

MCC14 – MCC13

are both non-zero

MCC13 is non-zero and

IPC61 must be within 00000

IPC61

MCC10 – MCC13.

MCC14 is zero

MCC13 is zero and

IPC61 must be within 00000

IPC61

MCC14 – MCC09

MCC14 is non-zero .

MCC13 and MCC14

IPC61 must be within 00000

IPC61

MCC10 – MCC09

are both zero

0462

IPC62 is out of range.
If non-zero, IPC62 must be within MCC17

IPC62

MCC18

0463

IPC63 is out of range.
If non-zero, IPC63 must be within MCC57

IPC63

MCC58

0464

IPC64 is out of range.
if:

then:

MCC13 and MCC14

IPC64 must be within 00000

IPC64

MCC14 – MCC13

are both non-zero

MCC13 is non-zero and

IPC64 must be within 00000

IPC64

MCC10 – MCC13.

MCC14 is zero

MCC13 is zero and

IPC64 must be within 00000

IPC64

MCC14 – MCC09.

MCC14 is non-zero

MCC13 and MCC14

IPC64 must be within 00000

IPC64

MCC10 – MCC09

are both zero

0503

You have selected Pressure Limited Vel/Pos execution for the Injection Profile by
IPC03-B01 = 0 and IPC03-B00 = 1; however, your bit patterns in MCC02 and MCC03 indi-
cate that the QDC module does not have access to a connected ram (screw) pressure
transducer.

0504

You have selected closed-loop Press/Pos execution for the Injection Profile by IPC04-B02 =
0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC module does not
have access to a connected ram (screw) pressure transducer.

0508

You have selected closed-loop Press/Time execution for the Injection Profile by IPC04-B03
= 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC module does
not have access to a connected ram (screw) pressure transducer.

0600

Your entire Injection Profile Command Block has been rejected because the QDC module
does not have a valid Injection Configuration Command Block on-board (SYS15-B07 = 0).

0711

IPC11 cannot be 00000 because it conflicts with one of:

IPC13 > 00000 when IPC03-B01 = 0

C 3

00000

C03 0

0

IPC14 > 00000 when IPC03-B01 = 1

0712

IPC12 cannot be 00000 when IPC14 > 00000.

0715

IPC15 cannot be 00000 because it conflicts with one of:

IPC17 > 00000 when IPC03-B01 = 0

IPC18 > 00000 when IPC03-B01 = 1

0716

IPC16 cannot be 00000 when IPC18 > 00000.

0719

IPC19 cannot be 00000 because it conflicts with one of:

IPC21 > 00000 when IPC03-B01 = 0

C

00000

C03 0

0

IPC22 > 00000 when IPC03-B01 = 1

0720

IPC20 cannot be 00000 when IPC22 > 00000.

0723

IPC23 cannot be 00000 because it conflicts with one of:

IPC25 > 00000 when IPC03-B01 = 0

C 5

00000

C03 0

0

IPC26 > 00000 when IPC03-B01 = 1

0724

IPC24 cannot be 00000 when IPC26 > 00000.