Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 258

Advertising
background image

4–34

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 15

0419

PPC19 is out of range.
if:

then:

MCC13 and MCC14

PPC19 must be within 00000

≤

PPC19

≤

MCC14 – MCC13

are both non-zero

MCC13 is non-zero and

PPC19 must be within 00000

≤

PPC19

≤

MCC10 – MCC13.

MCC14 is zero

MCC13 is zero and

PPC19 must be within 00000

≤

PPC19

≤

MCC14 – MCC09.

MCC14 is non-zero

MCC13 and MCC14

PPC19 must be within 00000

≤

PPC19

≤

MCC10 – MCC09

are both zero

0422

PPC22 is out of range.
If non-zero, PPC22 must be within PLC41

≤

PPC22

≤

PLC42

0423

PPC23 is out of range.
if:

then:

MCC13 and MCC14

PPC23 must be within 00000

≤

PPC23

≤

MCC14 – MCC13

are both non-zero

MCC13 is non-zero and

PPC23 must be within 00000

≤

PPC23

≤

MCC10 – MCC13.

MCC14 is zero

MCC13 is zero and

PPC23 must be within 00000

≤

PPC23

≤

MCC14 – MCC09

MCC14 is non-zero .

MCC13 and MCC14

PPC23 must be within 00000

≤

PPC23

≤

MCC10 – MCC09

are both zero

0426

PPC26 is out of range.
If non-zero, PPC26 must be within PLC41

≤

PPC26

≤

PLC42

0427

PPC27 is out of range.
if:

then:

MCC13 and MCC14

PPC27 must be within 00000

≤

PPC27

≤

MCC14 – MCC13

are both non-zero

MCC13 is non-zero and

PPC27 must be within 00000

≤

PPC27

≤

MCC10 – MCC13.

MCC14 is zero

MCC13 is zero and

PPC27 must be within 00000

≤

PPC27

≤

MCC14 – MCC09.

MCC14 is non-zero

MCC13 and MCC14

PPC27 must be within 00000

≤

PPC27

≤

MCC10 – MCC09

are both zero

0430

PPC30 is out of range.
If non-zero, PPC30 must be within PLC41

≤

PPC30

≤

PLC42

0431

PPC31 is out of range.
if:

then:

MCC13 and MCC14

PPC31 must be within 00000

≤

PPC31

≤

MCC14 – MCC13

are both non-zero

MCC13 is non-zero and

PPC31 must be within 00000

≤

PPC31

≤

MCC10 – MCC13.

MCC14 is zero

MCC13 is zero and

PPC31 must be within 00000

≤

PPC31

≤

MCC14 – MCC09.

MCC14 is non-zero

MCC13 and MCC14

PPC31 must be within 00000

≤

PPC31

≤

MCC10 – MCC09

are both zero

0434

PPC34 is out of range.
If non-zero, PPC34 must be within PLC41

≤

PPC34

≤

PLC42

Advertising