Id = 25 – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 279

Advertising
background image

4–55

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 24

0461

EPC61 is out of range.
if:

then:

MCC27 and MCC28

EPC61 must be within EPC62 < EPC61

MCC28 – MCC27

are both non-zero

MCC27 is non-zero and

EPC61 must be within EPC62 < EPC61

MCC24 – MCC27

MCC28 is zero

MCC27 is zero and

EPC61 must be within EPC62 < EPC61

MCC28 – MCC23

MCC28 is non-zero

MCC27 and MCC28

EPC61 must be within EPC62 < EPC61

MCC24 – MCC23

are both zero

0462

EPC62 is out of range. Valid range is 00000

EPC62 < EPC61

0463

EPC63 is out of range. Valid range is EPC60

EPC63 < EPC59

0503

Your selection to start the Ejector Profile based upon clamp position during the Clamp Open
Profile is invalid because QDC module does not have a valid OPC (SYS16-B04 = 0).

0504

You have selected closed-loop Press/Pos execution for the Ejector Profile by EPC04-B01 = 0;
however, your bit patterns in MCC02 and MCC03 indicate that the QDC module does not
have access to a connected ejector pressure transducer.

0600

Your entire Ejector Profile Command Block has been rejected because the QDC module does
not have both a valid Ejector Advance Configuration Command Block and a valid Ejector
Retract Configuration Command Block on-board.

0812

EPC12 must be 00000 when EPC11 = 00000.

0813

EPC13 must be 00000 when EPC11 = 00000.

0814

EPC14 must be 00000 when EPC11 = 00000.

0815

EPC15 must be 00000 when EPC14 = 00000.

0816

EPC16 must be 00000 when EPC14 = 00000.

0836

EPC36 must be 00000 when EPC35 = 00000.

0837

EPC37 must be 00000 when EPC35 = 00000.

0838

EPC38 must be 00000 when EPC35 = 00000.

0839

EPC39 must be 00000 when EPC38 = 00000.

0840

EPC40 must be 00000 when EPC38 = 00000.

1014

EPC14 is not in increasing positional order.
If non-zero, EPC14 must be greater than EPC11.

1038

EPC38 is not in decreasing positional order.
If non-zero, EPC38 must be less than EPC35.

ID = 25

DYC – Dynamic Command Block

Error Code

Description

ID = 25

0209

DYC09 is out of range. Valid range is 00000

DYC09

09999

0210

DYC10 is out of range. Valid range is 00000

DYC10

09999

0211

DYC11 is out of range. Valid range is 00000

DYC11

09999

0212

DYC12 is out of range. Valid range is 00000

DYC12

09999

0213

DYC13 is out of range. Valid range is 00000

DYC13

09999

0214

DYC14 is out of range. Valid range is 00000

DYC14

09999

0215

DYC15 is out of range. Valid range is 00000

DYC15

09999

0216

DYC16 is out of range. Valid range is 00000

DYC16

09999

0217

DYC17 is out of range. Valid range is 00000

DYC17

09999

0218

DYC18 is out of range. Valid range is 00000

DYC18

09999

0219

DYC19 is out of range. Valid range is 00000

DYC19

09999

0220

DYC20 is out of range. Valid range is 00000

DYC20

09999

Advertising