4–55

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 24

0461

EPC61 is out of range.
if:

then:

MCC27 and MCC28

EPC61 must be within EPC62 < EPC61

≤

MCC28 – MCC27

are both non-zero

MCC27 is non-zero and

EPC61 must be within EPC62 < EPC61

≤

MCC24 – MCC27

MCC28 is zero

MCC27 is zero and

EPC61 must be within EPC62 < EPC61

≤

MCC28 – MCC23

MCC28 is non-zero

MCC27 and MCC28

EPC61 must be within EPC62 < EPC61

≤

MCC24 – MCC23

are both zero

0462

EPC62 is out of range. Valid range is 00000

≤

EPC62 < EPC61

0463

EPC63 is out of range. Valid range is EPC60

≤

EPC63 < EPC59

0503

Your selection to start the Ejector Profile based upon clamp position during the Clamp Open
Profile is invalid because QDC module does not have a valid OPC (SYS16-B04 = 0).

0504

You have selected closed-loop Press/Pos execution for the Ejector Profile by EPC04-B01 = 0;
however, your bit patterns in MCC02 and MCC03 indicate that the QDC module does not
have access to a connected ejector pressure transducer.

0600

Your entire Ejector Profile Command Block has been rejected because the QDC module does
not have both a valid Ejector Advance Configuration Command Block and a valid Ejector
Retract Configuration Command Block on-board.

0812

EPC12 must be 00000 when EPC11 = 00000.

0813

EPC13 must be 00000 when EPC11 = 00000.

0814

EPC14 must be 00000 when EPC11 = 00000.

0815

EPC15 must be 00000 when EPC14 = 00000.

0816

EPC16 must be 00000 when EPC14 = 00000.

0836

EPC36 must be 00000 when EPC35 = 00000.

0837

EPC37 must be 00000 when EPC35 = 00000.

0838

EPC38 must be 00000 when EPC35 = 00000.

0839

EPC39 must be 00000 when EPC38 = 00000.

0840

EPC40 must be 00000 when EPC38 = 00000.

1014

EPC14 is not in increasing positional order.
If non-zero, EPC14 must be greater than EPC11.

1038

EPC38 is not in decreasing positional order.
If non-zero, EPC38 must be less than EPC35.

ID = 25

DYC – Dynamic Command Block

Error Code

Description

ID = 25

0209

DYC09 is out of range. Valid range is 00000

≤

DYC09

≤

09999

0210

DYC10 is out of range. Valid range is 00000

≤

DYC10

≤

09999

0211

DYC11 is out of range. Valid range is 00000

≤

DYC11

≤

09999

0212

DYC12 is out of range. Valid range is 00000

≤

DYC12

≤

09999

0213

DYC13 is out of range. Valid range is 00000

≤

DYC13

≤

09999

0214

DYC14 is out of range. Valid range is 00000

≤

DYC14

≤

09999

0215

DYC15 is out of range. Valid range is 00000

≤

DYC15

≤

09999

0216

DYC16 is out of range. Valid range is 00000

≤

DYC16

≤

09999

0217

DYC17 is out of range. Valid range is 00000

≤

DYC17

≤

09999

0218

DYC18 is out of range. Valid range is 00000

≤

DYC18

≤

09999

0219

DYC19 is out of range. Valid range is 00000

≤

DYC19

≤

09999

0220

DYC20 is out of range. Valid range is 00000

≤

DYC20

≤

09999

Advertising