Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 174

Advertising
background image

2–108

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

Bit

B04-B06

Selected Pressure Control Valve
The module uses its algorithm to drive the following output during any Press/Pos Third Clamp Open Profile.
B06 B05 B04
0 0 0 Output #1
0 0 1 Output #2
0 1 0 Output #3
0 1 1 Output #4
1 0 0 Output #5
1 0 1 Output #6
1 1 0 Output #7
1 1 1 Output #8

B07

Pressure Algorithm Selection
= 0 Dependent Gains (ISA)
= 1 Independent Gains (A-B)

B08-B15

Open

TOC03 - 04

Open

Expert Response Compensation (ERC) Percentage

Word

Description

TOC05

Minimum Velocity Control ERC Percentage [31]
Although error coding allows range of 00000 to 09999, the module limits it to a minimum of 01000.

TOC06

Minimum Pressure Control ERC Percentage [31]
Although error coding allows range of 00000 to 09999, the module limits it to a minimum of 01000.

TOC07

Open

Watchdog Timer

Word

Description

TOC08

Profile Watchdog Timer Preset [21] When the module starts the Third Clamp Open Profile, it:

S

starts an internal Profile Watchdog timer

S

stops the timer and reset accumulated value to zero (after reporting total execution time in OPS59) when it completes the profile

S

sets master status bit SYS04-B12 when the accumulated value of this timer equals or exceeds this entry

A zero entry inhibits SYS04-B12.

Unselected Valve Set-output Values

When the module starts the Third Clamp Open Profile, it:

sets its unselected outputs to the values listed below

ignores the unselected value of the selected output

uses ramp rates TOC17 - TOC32 to ramp unselected outputs

if

then

the module is commanded to start the
Ejector Profile during this TOC Profile

this TOC Profile surrenders control of the
unselected valve that is the selected
Ejector Profile valve

the module is commanded to start this TOC
Profile during the Ejector Profile

the Ejector Profile gives control of all of its
unselected valves to this TOC Profile

Third Clamp Open and Ejector Profiles are
run concurrently

all outputs that are unselected in both
profiles are controlled by this TOC Profile

Word

Description

TOC09

Output #1 Set-output Value during Profile [19]

TOC10

Output #2 Set-output Value during Profile [19]

TOC11

Output #3 Set-output Value during Profile [19]

TOC12

Output #4 Set-output Value during Profile [19]

Advertising