4–5

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 1

0432

MCC32 is out of range. Valid range is MCC31 < MCC32

09999

0435

MCC35 is out of range.
If non-zero, MCC35 must be within MCC31 < MCC35

MCC32

0437

MCC37 is out of range. Valid range is 00000

MCC37 < MCC38

0438

MCC38 is out of range. Valid range is MCC37 < MCC38

09999

0441

Your non-zero entry for MCC41 is out of range.
If MCC42 is non-zero, MCC41 must be within MCC37

MCC41 < MCC42

If MCC42 is zero, MCC41 must be within MCC37

MCC41 < MCC38

0442

Your non-zero entry for MCC42 is out of range.
If MCC41 is non-zero, MCC42 must be within MCC41 < MCC42

MCC38

If MCC41 is zero, MCC42 must be within MCC37 < MCC42

MCC38

0445

MCC45 is out of range. Valid range is 00000

MCC45 < MCC46

0446

MCC46 is out of range. Valid range is MCC45 < MCC46

09999

0449

MCC49 is out of range.
If non-zero, MCC49 must be within MCC45 < MCC49

MCC46

0451

MCC51 is out of range. Valid range is 00000

MCC51 < MCC52

0452

MCC52 is out of range. Valid range is MCC51 < MCC52

09999

0455

MCC55 is out of range.
If non-zero, MCC55 must be within MCC51 < MCC55

MCC52

0457

MCC57 is out of range. Valid range is 00000

MCC57 < MCC58

0458

MCC58 is out of range. Valid range is MCC57 < MCC58

20000

0461

MCC61 is out of range.
If non-zero, MCC61 must be within MCC57 < MCC61

MCC58

0502

You configured the module for 4x4 I/O by MCC02-B03 = 1.
Therefore, MCC02-B04 = 1 and MCC02-B05 = 1 is illegal.

0503

You configured the module for 4x4 I/O by MCC02-B03 = 1.
Therefore, your bit pattern in the upper byte of MCC03 must be 11111111 to indicate that
inputs #5 through #8 are “unconnected”.

0504

You configured the module for 4x4 I/O by MCC02-B03 = 1.
Therefore, your bit pattern in the upper byte of MCC04 must be 11111111 to indicate that
outputs #5 through #8 are “unconnected”.

0507

Your settings for MCC02-B03, B04, and B05 indicate that module input #1 is reserved for a
ram (screw) position transducer. Therefore MCC03-B00 and B01 cannot both = 1.

0511

Your settings for MCC02-B03, B04, and B05 indicate that module input #3 is reserved for a
clamp position transducer. Therefore MCC03-B00 and B01 cannot both = 1.

0602

You configured the module for 8x8 I/O by MCC02-B03 = 0.
This configuration is not supported by your series/revision of firmware.

0915

MCC15 is too large.
if:

then:

MCC13 and MCC14

MCC15 must be within MCC13 + MCC15 < MCC14 – MCC15

are both non-zero

MCC13 is zero and

MCC15 must be within MCC09 + MCC15 < MCC14 – MCC15

MCC14 is non-zero

MCC13 is non-zero

MCC15 must be within MCC13 + MCC15 < MCC10 – MCC15

and MCC14 is zero

0929

MCC29 is too large.
if:

then:

MCC27 and MCC28

MCC29 must be within MCC27 + MCC29 < MCC28 – MCC29

are both non-zero

MCC27 is zero and

MCC29 must be within MCC23 + MCC29 < MCC28 – MCC29

MCC28 is non-zero

MCC27 is non-zero

MCC29 must be within MCC27 + MCC29 < MCC24 – MCC29

and MCC28 is zero