Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 228

Advertising
background image

4–4

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 1

0248

MCC48 is out of range. MCC48 must be within:
00000

MCC48

01000 (0 to 10 V dc sensor)

00100

MCC48

00500 (1 to 5 V dc sensor)

00400

MCC48

02000 (4 to 20 mA dc sensor)

0250

MCC50 is out of range. Valid range is 00000

MCC50

00099

0253

MCC53 is out of range. MCC53 must be within:
00000

MCC53

01000 (0 to 10 V dc sensor)

00100

MCC53

00500 (1 to 5 V dc sensor)

00400

MCC53

02000 (4 to 20 mA dc sensor)

0254

MCC54 is out of range. MCC54 must be within:
00000

MCC54

01000 (0 to 10 V dc sensor)

00100

MCC54

00500 (1 to 5 V dc sensor)

00400

MCC54

02000 (4 to 20 mA dc sensor)

0256

MCC56 is out of range. Valid range is 00000

MCC56

00099

0259

MCC59 is out of range. MCC59 must be within:
00000

MCC59

01000 (0 to 10 V dc sensor)

00100

MCC59

00500 (1 to 5 V dc sensor)

00400

MCC59

02000 (4 to 20 mA dc sensor)

0260

MCC60 is out of range. MCC60 must be within
00000

MCC60

01000 (0 to 10 V dc sensor)

00100

MCC60

00500 (1 to 5 V dc sensor)

00400

MCC60

02000 (4 to 20 mA dc sensor)

0262

MCC62 is out of range. Valid range is 00000

MCC62

00099

0311

MCC11 is equal to MCC12. They must not be equal.

0319

MCC19 is equal to MCC20. They must not be equal.

0325

MCC25 is equal to MCC26. They must not be equal.

0333

MCC33 is equal to MCC34. They must not be equal.

0339

MCC39 is equal to MCC40. They must not be equal.

0347

MCC47 is equal to MCC48. They must not be equal.

0353

MCC53 is equal to MCC54. They must not be equal.

0359

MCC59 is equal to MCC60. They must not be equal.

0405-0408

Your entry for MCC05-MCC08 is out of range. Valid range is –1000

entry

+1000.

0409

MCC09 is out of range. Valid range is 00000

MCC09 < MCC10

0410

MCC10 is out of range. Valid range is MCC09 < MCC10

09999

0413

Your non-zero entry for MCC13 is out of range. If MCC14 is non-zero, MCC13 must be
within MCC09

MCC13 < MCC14

If MCC14 is zero, MCC13 must be within MCC09

MCC13 < MCC10

0414

Your non-zero entry for MCC14 is out of range. If MCC13 is non-zero, MCC14 must be
within MCC13 < MCC14

MCC10

If MCC13 is zero, MCC14 must be within MCC09 < MCC14

MCC10

0417

MCC17 is out of range. Valid range is 00000

MCC17 < MCC18

0418

MCC18 is out of range. Valid range is MCC17 < MCC18

09999

0421

MCC21 is out of range.
If non-zero, MCC21 must be within MCC17 < MCC21

MCC18

0423

MCC23 is out of range. Valid range is 00000

MCC23 < MCC24

0424

MCC24 is out of range. Valid range is MCC23 < MCC24

09999

0427

Your non-zero entry for MCC27 is out of range.
If MCC28 is non-zero, MCC27 must be within MCC23

MCC27 < MCC28

If MCC28 is zero, MCC27 must be within MCC23

MCC27 < MCC24

0428

Your non-zero entry for MCC28 is out of range.
If MCC27 is non-zero, MCC28 must be within MCC27 < MCC28

MCC24

If MCC27 is zero, MCC28 must be within MCC23 < MCC28

MCC24

0431

MCC31 is out of range. Valid range is 00000

MCC31 < MCC32

Advertising