Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 153

Advertising
background image

2–87

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

PLC

Word

Description

PLC33

Output #1 Set-output Value at End of Profile [19]

PLC34

Output #2 Set-output Value at End of Profile [19]

PLC35

Output #3 Set-output Value at End of Profile [19]

PLC36

Output #4 Set-output Value at End of Profile [19]

PLC37

Output #5 Set-output Value at End of Profile [19]

PLC38

Output #6 Set-output Value at End of Profile [19]

PLC39

Output #7 Set-output Value at End of Profile [19]

PLC40

Output #8 Set-output Value at End of Profile [19]

Pressure Control Limits

Word

Description

PLC41

Pressure Minimum Control Limit [01] Minimum controllable ram (screw) pressure attainable during any Press/Pos or Press/Time
Plastication Profile. The module expects this ram (screw) pressure when setting its selected valve to the %-output in PLC43.

PLC42

Pressure Maximum Control Limit [01] Maximum controllable ram (screw) pressure attainable during any Press/Pos or Press/Time
Plastication Profile. The module expects this ram (screw) pressure when setting its selected valve to the %-output in PLC44.

PLC43

Selected Pressure Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected pressure
valve during any Press/Pos or Press/Time Plastication Profile. The module expects a pressure equal to PLC41 when setting the
selected pressure valve to this %-output during profile execution. The profile will be executed as a reverse-acting algorithm if this
entry is greater than PLC44.

PLC44

Selected Pressure Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected pressure
valve during any Press/Position or Press/Time Plastication Profile. The module expects a pressure equal to PLC42 when setting the
selected pressure valve to this %-output during profile execution. The profile will be executed as a reverse-acting algorithm if this
entry is less than PLC43.

RPM Control Limits

Word

Description

PLC45

RPM Minimum Control Limit [25] Minimum controllable RPM attainable during any RPM/Pos or RPM/Time Plastication Profile. The
module expects this RPM when setting its selected valve to the %-output in PLC47.

PLC46

RPM Maximum Control Limit [25] Maximum controllable RPM attainable during any RPM/Pos or RPM/Time Plastication Profile. The
module expects this RPM when setting its selected valve to the %-output in PLC48.

PLC47

Selected RPM Valve Output for Minimum [19] 0% CV output (%) that the module uses to drive the selected RPM valve during any
Press/Position or Press/Time Plastication Profile. The module expects an RPM equal to PLC45 when setting the selected RPM
valve to this %-output during profile execution. The profile will be executed as reverse-acting if this entry is greater than PLC48.

PLC48

Selected RPM Valve Output for Maximum [19] 100% CV output (%) that the module uses to drive the selected RPM valve during
any Press/Position or Press/Time Plastication Profile. The module expects an RPM equal to PLC46 when setting the selected RPM
valve to this %-output during profile execution. The profile will be executed as reverse-acting if this entry is less than PLC47.

Profile Tuning Constants

Word

Description

PLC49

Proportional Gain for Pressure Control [30]

PLC50

Integral Gain for Pressure Control [27] or [28]

PLC51

Derivative Gain for Pressure Control [26] or [21]

PLC52

Proportional Gain for RPM Control [30]

PLC53

Integral Gain for RPM Control [27] or [28]

PLC54

Derivative Gain for RPM Control [26] or [21]

PLC55 - 56

Open

Profile Pressure Alarm Setpoint

Word

Description

PLC57

Profile High Pressure Alarm Setpoint [01] The module compares real-time ram (screw) pressure against this entry when executing
the Plastication Profile. The module sets alarm status bit SYS06-B07 when ram (screw) pressure equals or exceeds this entry
during the Plastication Profile. A zero entry inhibits SYS06-B07.

PLC58 - 64

Open