Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 9

0727

IPC27 cannot be 00000 because it conflicts with one of:

IPC29 > 00000 when IPC03-B01 = 0

C 9

00000

C03 0

0

IPC30 > 00000 when IPC03-B01 = 1

0728

IPC28 cannot be 00000 when IPC30 > 00000.

0731

IPC31 cannot be 00000 because it conflicts with one of:

IPC33 > 00000 when IPC03-B01 = 0

C33

00000

C03 0

0

IPC34 > 00000 when IPC03-B01 = 1

0732

IPC32 cannot be 00000 when IPC34 > 00000.

0735

IPC35 cannot be 00000 because it conflicts with one of:

IPC37 > 00000 when IPC03-B01 = 0

IPC37 > 00000 when IPC03-B01 = 0

IPC38 > 00000 when IPC03-B01 = 1

0736

IPC36 cannot be 00000 when IPC38 > 00000.

0739

IPC39 cannot be 00000 because it conflicts with one of:

IPC41 > 00000 when IPC03-B01 = 0

C

00000

C03 0

0

IPC42 > 00000 when IPC03-B01 = 1

0740

IPC40 cannot be 00000 when IPC42 > 00000.

0743

IPC43 cannot be 00000 because it conflicts with one of:

IPC45 > 00000 when IPC03-B01 = 0

C 5

00000

C03 0

0

IPC46 > 00000 when IPC03-B01 = 1

0744

IPC44 cannot be 00000 when IPC46 > 00000.

0747

IPC47 cannot be 00000 because it conflicts with one of:

IPC49 > 00000 when IPC03-B01 = 0

C 9

00000

C03 0

0

IPC50 > 00000 when IPC03-B01 = 1

0748

IPC48 cannot be 00000 when IPC50 > 00000.

0757

You have selected Pressure Limited Vel/Pos execution for the Injection Profile by
IPC03-B01 = 0 and IPC03-B00 = 1. This mode of Injection Profile execution does not allow
a 00000 entry for IPC57.

0815

IPC15 must be 00000 when IPC11 = 00000.

0816

IPC16 must be 00000 when IPC12 = 00000.

0819

IPC19 must be 00000 when IPC15 = 00000.

0820

IPC20 must be 00000 when IPC16 = 00000.

0823

IPC23 must be 00000 when IPC19 = 00000.

0824

IPC24 must be 00000 when IPC20 = 00000.

0827

IPC27 must be 00000 when IPC23 = 00000.

0828

IPC28 must be 00000 when IPC24 = 00000.

0831

IPC31 must be 00000 when IPC27 = 00000.

0832

IPC32 must be 00000 when IPC28 = 00000.

0835

IPC35 must be 00000 when IPC31 = 00000.

0836

IPC36 must be 00000 when IPC32 = 00000.

0839

IPC39 must be 00000 when IPC35 = 00000.

0840

IPC40 must be 00000 when IPC36 = 00000.

0843

IPC43 must be 00000 when IPC39 = 00000.

0844

IPC44 must be 00000 when IPC40 = 00000.

0847

IPC47 must be 00000 when IPC43 = 00000.

0848

IPC48 must be 00000 when IPC44 = 00000.

0862

IPC62 must be zero because your bit patterns in MCC02 and MCC03 indicate that the QDC
module does not have access to a connected ram (screw) pressure transducer.

0863

IPC63 must be zero because your bit patterns in MCC02 and MCC03 indicate that the QDC
module has no access to a connected cavity pressure transducer.