Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 273

Advertising
background image

4–49

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 21

0633

Your OPC33 must be zero because TOC is invalid (SYS16-B02 = 0).

0634

Your OPC34 must be zero because TOC is invalid (SYS16-B02 = 0).

0635

Your OPC35 must be zero because TOC is invalid (SYS16-B02 = 0).

0812

OPC12 must be 00000 when OPC11 = 00000.

0813

OPC13 must be 00000 when OPC11 = 00000.

0814

OPC14 must be 00000 when OPC11 = 00000.

0815

OPC15 must be 00000 when OPC14 = 00000.

0816

OPC16 must be 00000 when OPC14 = 00000.

0817

OPC17 must be 00000 when OPC14 = 00000.

0821

OPC21 must be 00000 when OPC20 = 00000.

0822

OPC22 must be 00000 when OPC20 = 00000.

0823

OPC23 must be 00000 when OPC20 = 00000.

0824

OPC24 must be 00000 when OPC23 = 00000.

0825

OPC25 must be 00000 when OPC23 = 00000.

0826

OPC26 must be 00000 when OPC23 = 00000.

0830

OPC30 must be 00000 when OPC29 = 00000.

0831

OPC31 must be 00000 when OPC29 = 00000.

0832

OPC32 must be 00000 when OPC29 = 00000.

0833

OPC33 must be 00000 when OPC32 = 00000.

0834

OPC34 must be 00000 when OPC32 = 00000.

0835

OPC35 must be 00000 when OPC32 = 00000.

0839

OPC39 must be 00000 when OPC38 = 00000.

0840

OPC40 must be 00000 when OPC38 = 00000.

1014

OPC14 is not in increasing positional order.
If non-zero, OPC14 must be greater than OPC11.

1017

OPC17 is not in increasing positional order.
If non-zero, OPC17 must be greater than OPC14.

1020

OPC20 is not in increasing positional order.
If non-zero, OPC20 must be greater than OPC11, OPC14, and OPC17.

1023

OPC23 is not in increasing positional order.
If non-zero, OPC23 must be greater than OPC20.

1026

OPC26 is not in increasing positional order.
If non-zero, OPC26 must be greater than OPC23.

1029

OPC29 is not in increasing positional order. If non-zero, OPC29 must be greater than OPC11,
OPC14, OPC17, OPC20, OPC23, and OPC26.

1032

OPC32 is not in increasing positional order.
If non-zero, OPC32 must be greater than OPC29.

1035

OPC35 is not in increasing positional order.
If non-zero, OPC35 must be greater than OPC32.

1038

OPC38 is not in increasing positional order. If non-zero, OPC38 must be greater than OPC11,
OPC14, OPC17, OPC20, OPC23, OPC26, OPC29, OPC32, and OPC35.

0209

CLC09 is out of range. Valid range is 00000

≤

CLC09

≤

09999

0210

CLC10 is out of range. Valid range is 00000

≤

CLC10

≤

09999

0211

CLC11 is out of range. Valid range is 00000

≤

CLC11

≤

09999

0212

CLC12 is out of range. Valid range is 00000

≤

CLC12

≤

09999

0213

CLC13 is out of range. Valid range is 00000

≤

CLC13

≤

09999

0214

CLC14 is out of range. Valid range is 00000

≤

CLC14

≤

09999

0215

CLC15 is out of range. Valid range is 00000

≤

CLC15

≤

09999

0216

CLC16 is out of range. Valid range is 00000

≤

CLC16

≤

09999

0217

CLC17 is out of range. Valid range is 00000

≤

CLC17

≤

09999

Advertising