Mcc - module configuration command block, Mcc – module configuration command block – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 134

Advertising
background image

2–68

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Bit-mapped Control Words

Word

Bit

Description

MCC01

B00 - B07

Block ID 00000001

B08 - B15

Reserved for the module. Do not use.

MCC02

MCC Configuration Selections

B00

Data Range Selection

0

English Units (Inches and PSI)

0 = English Units (Inches and PSI)
1 = Metric Units (Millimeters and Bar)

B01

Module designation for co-injection
0 = QIA
1 = QIB

B02

Open

B03

Module I/O Density

B03

Module I/O Density

0 = invalid

0 = invalid
1 = Four/Four I/O (required selection)

Four/Four I/O Configuration

Four/Four I/O Configuration

MUST BE SET. The module configures itself as a 1-slot module containing four inputs and four outputs,

MUST BE SET. The module configures itself as a 1 slot module containing four in uts and four out uts,
and accesses bits MCC02-B04 and MCC02-B05 to determine layout of its inputs.

B04 -B05

B05

B04

Four/Four I/O Configuration

0

0

Inject Control

0

1

Inject and Clamp Control

1

0

Clamp and Eject Control

1

0

Clam and Eject Control

1

1

Inject, Clamp, and Eject Control

B05

B04

Input #1

Input #2

Input #3

Input #4

0

0

Ram (Screw) Position

Ram (Screw) Pressure

Screw RPM

Cavity Pressure

0

1

R

(S

) P iti

R

(S

) P

Cl

P iti

Cl

P

(

)

(

)

y

0

1

Ram (Screw) Position

Ram (Screw) Pressure

Clamp Position

Clamp Pressure

1

0

Ejector Position

Ejector Pressure

Clamp Position

Clamp Pressure

1

1

Ram (Screw) Position

System Pressure

Clamp Position

Ejector Position

The module accesses these bits only if MCC02-B03 is SET.

B06-B07

Open

B08

inhibit (override) loss of sensor protection for screw position input

B09

Inhibit (override) loss of sensor protection for screw pressure input

B10

Inhibit (override) loss of sensor protection for clamp position input

B11

Inhibit (override) loss of sensor protection for clamp pressure input

B12

Inhibit (override) loss of sensor protection for ejector position input

B13

Inhibit (override) loss of sensor protection for ejector pressure input

B14

Inhibit (override) loss of sensor protection for screw RPM input

B15

Inhibit (override) loss of sensor protection for cavity pressure input (system pressure in Inject-Clamp-Eject mode)

MCC – Module Configuration
Command Block