Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 105

Advertising
background image

2–39

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

ERC

Word

Description

ERC29

Output #5 Deceleration Ramp Rate during Retract [20]

ERC30

Output #6 Deceleration Ramp Rate during Retract [20]

ERC31

Output #7 Deceleration Ramp Rate during Retract [20]

ERC32

Output #8 Deceleration Ramp Rate during Retract [20]

End of Retract Set-output Values

At the end of each retract stroke during the Ejector Profile, the
module checks the following to determine further control action:

state of EPC03-B12

states of SYS21-B10 through SYS21-B13

completion status of the Ejector Profile

if

and

and

then the module:

EPC03-B12= 0 B10-B13 in SYS21 all

= 0

Ejector Profile is complete

uses the ramps ERC17-ERC32 to move its outputs to ERC33-ERC40,
and sets status bit SYS22-B15

EPC03-B12= 0 any one of B10-B13

in SYS21 = 1

Ejector Profile is complete

ignores ERC33-ERC40 and gives all output control to the executing
Clamp Open Profile

EPC03-B12= 0 N/A

Ejector Profile is incomplete

ignores ERC33-ERC40 and continues the Ejector Profile

EPC03-B12= 1 B10-B13 in SYS21 all

= 0

N/A

uses the ramps ERC17-ERC32 to move its outputs to ERC33-ERC40,
and sets status bit SYS22-B15

EPC03-B12= 1 any one of B10-B13

in SYS21 = 1

N/A

ignores ERC33-ERC40 and gives all output control to the executing
Clamp Open Profile

Word

Description

ERC33

Output #1 Set-output Value at End of Retract [19]

ERC34

Output #2 Set-output Value at End of Retract [19]

ERC35

Output #3 Set-output Value at End of Retract [19]

ERC36

Output #4 Set-output Value at End of Retract [19]

ERC37

Output #5 Set-output Value at End of Retract [19]

ERC38

Output #6 Set-output Value at End of Retract [19]

ERC39

Output #7 Set-output Value at End of Retract [19]

ERC40

Output #8 Set-output Value at End of Retract [19]

Pressure Control Limits

Word

Description

ERC41

Retract stroke Pressure Minimum Control Limit [03] Minimum controllable ejector-retract pressure attainable during any Press/Pos
Ejector Profile retract stroke. The module expects this ejector- retractpressure when setting its selected pressure retract valve to the
%- output in ERC43.

ERC42

Retract stroke Pressure Maximum Control Limit [03] Maximum controllable ejector-retract pressure attainable during any Press/Pos
Ejector Profile retract stroke. The module expects this ejector- retract pressure when setting its selected pressure retract valve to the
%- output in ERC44.

ERC43

Selected Pressure Retract Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected
pressure retract valve during any Press/Pos Ejector Profile. The module expects a pressure equal to ERC41 when setting the se-
lected pressure retract valve to this %-output during stroke execution. The Press/Pos Ejector Profile retract stroke will be executed
as a reverse-acting algorithm if this entry is greater than ERC44.

ERC44

Selected Pressure Retract Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected
pressure retract valve during any Press/Pos Ejector Profile. The module expects a pressure equal to ERC42 when setting the se-
lected pressure retract valve to this %-output during stroke execution. The Press/Pos Ejector Profileretract stroke will be executed
as a reverse-acting algorithm if this entry is less than ERC43.

Advertising