Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 278

Advertising
background image

4–54

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 24

0429

EPC29 is out of range.
if:

then:

MCC41 and MCC42

EPC29 must be within 00000

≤

EPC29

≤

MCC42 – MCC41

are both non-zero

MCC41 is non-zero and

EPC29 must be within 00000

≤

EPC29

≤

MCC38 – MCC41

MCC42 is zero

MCC41 is zero and

EPC29 must be within 00000

≤

EPC29

≤

MCC42 – MCC37

MCC42 is non-zero

MCC41 and MCC42

EPC29 must be within 00000

≤

EPC29

≤

MCC38 – MCC37

are both zero

0433

EPC33 is out of range. When EPC03-B14 = 1, a non-zero entry for EPC33 must be within
ERC45

≤

EPC33

≤

ERC46

0434

EPC34 is out of range. If non-zero, EPC34 must be within ERC41

≤

EPC34

≤

ERC42

0435

EPC35 is out of range.
if:

then:

MCC41 and MCC42

EPC35 must be within 00000

≤

EPC35 < MCC42 – MCC41

are both non-zero

MCC41 is non-zero and

EPC35 must be within 00000

≤

EPC35

≤

MCC38 – MCC41

MCC42 is zero

MCC41 is zero and

EPC35 must be within 00000

≤

EPC35 < MCC42 – MCC37

MCC42 is non-zero

MCC41 and MCC42

EPC35 must be within 00000

≤

EPC35

≤

MCC38 – MCC37

are both zero

0436

EPC36 is out of range. When EPC03-B14 = 1, a non-zero entry for EPC36 must be within
ERC45

≤

EPC36

≤

ERC46

0437

EPC37 is out of range. If non-zero, EPC37 must be within ERC41

≤

EPC37

≤

ERC42

0438

EPC38 is out of range.
if:

then:

MCC41 and MCC42

EPC38 must be within 00000

≤

EPC38

≤

MCC42 – MCC41

are both non-zero

MCC41 is non-zero and

EPC38 must be within 00000

≤

EPC38

≤

MCC38 – MCC41

MCC42 is zero

MCC41 is zero and

EPC38 must be within 00000

≤

EPC38

≤

MCC42 – MCC37

MCC42 is non-zero

MCC41 and MCC42

EPC38 must be within 00000

≤

EPC38

≤

MCC38 – MCC37

are both zero

0439

EPC39 is out of range. When EPC03-B14 = 1, a non-zero entry for EPC39 must be within
ERC45

≤

EPC39

≤

ERC46

0440

EPC40 is out of range. If non-zero, EPC40 must be within ERC41

≤

EPC40

≤

ERC42

0459

EPC59 is out of range.
if:

then:

MCC41 and MCC42

EPC59 must be within EPC60 < EPC59

≤

MCC42 – MCC41

are both non-zero

MCC41 is non-zero and

EPC59 must be within EPC60 < EPC59

≤

MCC38 – MCC41

MCC42 is zero

MCC41 is zero and

EPC59 must be within EPC60 < EPC59

≤

MCC42 – MCC37

MCC42 is non-zero

MCC41 and MCC42

EPC59 must be within EPC60 < EPC59

≤

MCC38 – MCC37

are both zero

0460

EPC60 is out of range. Valid range is 00000

≤

EPC60 < EPC59

Advertising