3–44

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

Bit

SYS21

B08

= 0 Normal
= 1 Plastication Profile in Progress
The module sets this bit when it starts the profile.

The module resets this bit when:

S

it completes the profile, or

S

it receives a new action execution command that terminates the profile

Module does not leave this bit set when holding outputs to PLC33 - 40 at completion of the plastication profile.

B09

= 0 Normal
= 1 Post-decompression Movement in Progress
The module sets this bit when it starts the movement.

The module resets this bit when:

S

it completes the movement, or

S

it receives a new action execution command that terminates the movement

Module does not leave this bit set when holding outputs to PSC33 - 40 at completion of Post-decompression movement

B10

= 0 Normal
= 1 First Clamp Open Profile in Progress
The module sets this bit when it starts the profile.

The module resets this bit when:

S

it completes the profile, or

S

it receives a new action execution command that terminates the profile

Module does not leave this bit set when holding outputs to FOC33 - 40 at completion of the First Clamp Open profile.

B11

= 0 Normal
= 1 Second Clamp Open Profile in Progress
The module sets this bit when it starts the profile.

The module resets this bit when:

S

it completes the profile, or

S

it receives a new action execution command that terminates the profile

Module does not leave this bit set when holding outputs to SOC33 - 40 at completion of the second clamp open profile.

B12

= 0 Normal
= 1 Third Clamp Open Profile in Progress
The module sets this bit when it starts the profile.

The module resets this bit when:

S

it completes the profile, or

S

it receives a new action execution command that terminates the profile

Module does not leave this bit set when holding outputs to TOC33 - 40 at completion of the third clamp open profile.

B13

= 0 Normal
= 1 Clamp Open Slow Profile in Progress
The module sets this bit when it starts the profile

The module resets this bit when:

S

it completes the profile, or

S

it receives a new action execution command that terminates the profile

Module does not leave this bit set when holding outputs to OSC33 - 40 at completion of the clamp open slow profile.

B14

= 0 Normal
= 1 Ejector Profile in Progress
The module sets this bit when it starts the profile.

The module resets this bit when:

S

it completes the profile, or

S

it receives a new action execution command that terminates the profile

The module does not leave this bit set when holding outputs to ERC33 - 40 at completion of the ejector profile.

B15