2–11

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

CPC

Word

Description

CPC21

Segment 5 Velocity Setpoint [07] or [08]
if:

then the module:

you select Vel/Pos profile execution

controls clamp close speed to this setpoint from the clamp position CPC20 until clamp
position reaches the larger of CPC23 or CPC61

CPC03-B14 is RESET

reads this parameter in percent velocity

CPC03-B14 is SET

reads it in in.(mm)/s

CPC22

Segment 5 Pressure Setpoint [02]
if:

then the module:

you select Press/Pos profile execution

controls clamp close pressure to this setpoint from the clamp position CPC20 until clamp
position reaches the larger of CPC23 or CPC61

CPC23

End of Segment 5 Position Setpoint [14]

CPC24

Segment 6 Velocity Setpoint [07] or [08]
if:

then the module:

you select Vel/Pos profile execution

controls clamp close speed to this setpoint from the clamp position CPC23 until clamp
position reaches the larger of CPC26 or CPC61

CPC03-B14 is RESET

reads this parameter in percent velocity

CPC03-B14 is SET

reads it in in.(mm)/s

CPC25

Segment 6 Pressure Setpoint [02]
if:

then the module:

you select Press/Pos profile execution

controls clamp close pressure to this setpoint from the clamp position CPC23 until clamp
position reaches the larger of CPC26 or CPC61

CPC26

End of Segment 6 Position Setpoint [14]

Third Clamp Close Profile Setpoints

Word

Description

CPC27

Segment 7 Velocity Setpoint [07] or [08]
if:

then the module:

you select Vel/Pos profile execution

controls clamp close speed to this setpoint after starting the Third Clamp Close Profile
until clamp position reaches the larger of CPC29 or CPC61

CPC03-B14 is RESET

reads this parameter in percent velocity

CPC03-B14 is SET

reads it in in.(mm)/s

CPC28

Segment 7 Pressure Setpoint [02]
if:

then the module:

you select Press/Pos profile execution

controls clamp close pressure to this setpoint after starting the Third Clamp Close Profile
until clamp position reaches the larger of CPC29 or CPC61

CPC29

End of Segment 7 Position Setpoint [14]

CPC30

Segment 8 Velocity Setpoint [07] or [08]
if:

then the module:

you select Vel/Pos profile execution

controls clamp close speed to this setpoint from the clamp position CPC29 until clamp
position reaches the larger of CPC32 or CPC61

CPC03-B14 is RESET

reads this parameter in percent velocity

CPC03-B14 is SET

reads it in in.(mm)/s

CPC31

Segment 8 Pressure Setpoint [02]
if:

then the module:

you select Press/Pos profile execution

controls clamp close pressure to this setpoint from the clamp position CPC29 until clamp
position reaches the larger of CPC32 or CPC61

CPC32

End of Segment 8 Position Setpoint [14]

CPC33

Segment 9 Velocity Setpoint [07] or [08]
if:

then the module:

you select Vel/Pos profile execution

controls clamp close speed to this setpoint from the clamp position CPC32 until clamp
position reaches the larger of CPC35 or CPC61

CPC03-B14 is RESET

reads this parameter in percent velocity

CPC03-B14 is SET

reads it in in.(mm)/s

Advertising