Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 9

0429

IPC29 is out of range.
When IPC03-B14 = 1, a non-zero IPC29 must be within INC45

IPC29

INC46

0430

IPC30 is out of range.
If non-zero, IPC30 must be within INC41

IPC30

INC42

0431

IPC31 is out of range.
if:

then:

MCC13 and MCC14

IPC31 must be within 00000

IPC31

MCC14 – MCC13

are both non-zero

MCC13 is non-zero and

IPC31 must be within 00000

IPC31

MCC10 – MCC13.

MCC14 is zero

MCC13 is zero and

IPC31 must be within 00000

IPC31

MCC14 – MCC09

MCC14 is non-zero .

If MCC13 and MCC14

IPC31 must be within 00000

IPC31

MCC10 – MCC09

are both zero

0433

IPC33 is out of range.
When IPC03-B14 = 1, a non-zero IPC33 must be within INC45

IPC33

INC46

0434

IPC34 is out of range.
If non-zero, IPC34 must be within INC41

IPC34

INC42

0435

IPC35 is out of range.
if:

then:

MCC13 and MCC14

IPC35 must be within 00000

IPC35

MCC14 – MCC13

are both non-zero

MCC13 is non-zero and

IPC35 must be within 00000

IPC35

MCC10 – MCC13.

MCC14 is zero

MCC13 is zero and

IPC35 must be within 00000

IPC35

MCC14 – MCC09

MCC14 is non-zero

MCC13 and MCC14

IPC35 must be within 00000

IPC35

MCC10 – MCC09

are both zero

0437

IPC37 is out of range.
When IPC03-B14 = 1, a non-zero IPC37 must be within INC45

IPC37

INC46

0438

IPC38 is out of range.
If non-zero, IPC38 must be within INC41

IPC38

INC42

0439

IPC39 is out of range.
if:

then:

MCC13 and MCC14

IPC39 must be within 00000

IPC39

MCC14 – MCC13

are both non-zero

MCC13 is non-zero and

IPC39 must be within 00000

IPC39

MCC10 – MCC13.

MCC14 is zero

MCC13 is zero and

IPC39 must be within 00000

IPC39

MCC14 – MCC09.

MCC14 is non-zero

MCC13 and MCC14

IPC39 must be within 00000

IPC39

MCC10 – MCC09

are both zero

0441

IPC41 is out of range.
When IPC03-B14 = 1, a non-zero IPC41 must be within INC45

IPC41

INC46

0442

IPC42 is out of range.
If non-zero, IPC42 must be within INC41

IPC42

INC42