2–28

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

EAC17

Output #1 Acceleration Ramp Rate during Advance [20]

EAC18

Output #2 Acceleration Ramp Rate during Advance [20]

EAC19

Output #3 Acceleration Ramp Rate during Advance [20]

EAC20

Output #4 Acceleration Ramp Rate during Advance [20]

EAC21

Output #5 Acceleration Ramp Rate during Advance [20]

EAC22

Output #6 Acceleration Ramp Rate during Advance [20]

EAC23

Output #7 Acceleration Ramp Rate during Advance [20]

EAC24

Output #8 Acceleration Ramp Rate during Advance [20]

EAC25

Output #1 Deceleration Ramp Rate during Advance [20]

EAC26

Output #2 Deceleration Ramp Rate during Advance [20]

EAC27

Output #3 Deceleration Ramp Rate during Advance [20]

EAC28

Output #4 Deceleration Ramp Rate during Advance [20]

EAC29

Output #5 Deceleration Ramp Rate during Advance [20]

EAC30

Output #6 Deceleration Ramp Rate during Advance [20]

EAC31

Output #7 Deceleration Ramp Rate during Advance [20]

EAC32

Output #8 Deceleration Ramp Rate during Advance [20]

End of Advance Set-output Values

At the end of each advance stroke during the Ejector Profile, the
module checks the following to determine further control action:

state of EPC03-B12

states of SYS21-B10 - SYS21-B13

if

then the module

EPC03-B12 = 0

ignores EAC33 - EAC40 and continues the Ejector Profile

EPC03-B12 = 1 and
SYS21-B10 through B13 all
bits = 0

uses the ramps EAC17 - EAC32 to move its outputs to
EAC33 - EAC40, and sets status bit SYS22-B14

EPC03-B12 = 1 and
SYS21-B10 through B13 any
bit = 1

ignores EAC33 - EAC40 and gives all output control to
the executing Clamp Open Profile

Word

Description

EAC33

Output #1 Set-output Value at End of Advance [19]

EAC34

Output #2 Set-output Value at End of Advance [19]

EAC35

Output #3 Set-output Value at End of Advance [19]

EAC36

Output #4 Set-output Value at End of Advance [19]

EAC37

Output #5 Set-output Value at End of Advance [19]

EAC38

Output #6 Set-output Value at End of Advance [19]

EAC39

Output #7 Set-output Value at End of Advance [19]

EAC40

Output #8 Set-output Value at End of Advance [19]