Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

Bit

SYS19

Programming-error Alarms

The module latches bits when it attempts to decode a newly received copy of the subject command block and is forced
to discard the data due to the presence of a programming error in the newly received block. The module does not latch
any bit associated with an unrecognizable command block. The module unlatches each bit when it successfully de-
codes the referenced command block and places the new data into operational memory.

When this bit
is latched ON:

the module detected a programming error in:

B00

MCC The module ceases all action execution and sets its outputs to zero when forced to set this bit. The module

does not respond to any action execution commands as long as this bit remains SET.

B01

JGC

B02

FCC

B03

SCC

B04

TCC

B05

LPC

B06

CPC

B07

INC

B08

IPC

B09

PKC

B10

HDC

B11

HPC

B12

PRC

B13

PLC

B14

PPC

B15

PSC

SYS20

Programming-error Alarms

The module latches bits when it attempts to decode a newly received copy of the subject command block and is forced
to discard the data due to the presence of a programming error in the newly received block. The module does not latch
any bit associated with an unrecognizable command block. The module unlatches each bit when it successfully de-
codes the referenced command block and places the new data into operational memory.

When this bit
is latched ON:

the module detected a programming error in:

B00

FOC

B01

SOC

B02

TOC

B03

OSC

B04

OPC

When this bit
is latched ON:

the module detected a programming error in:

B05

EAC

B06

ERC

B07

EPC

B08

DYC The module ceases all action execution and sets its outputs to zero when forced to set this bit. The module

does not respond to any action execution commands as long as this bit remains SET.

B09

RLC

B10

CLC

B11

PTC

B12-B15

Open