Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 120

Advertising
background image

2–54

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

Bit

B04-B06

Selected Pressure Control Valve
The module uses its algorithm to drive the following output during any Press/Pos or Press/Time Injection Profile.
B06 B05 B04
0 0 0 Output #1
0 0 1 Output #2
0 1 0 Output #3
0 1 1 Output #4
1 0 0 Output #5
1 0 1 Output #6
1 1 0 Output #7
1 1 1 Output #8

B07

Pressure Algorithm Selection
= 0 Dependent Gains (ISA)
= 1 Independent Gains (A-B)

B08-B15

Open

INC03 - 04

Open

Expert Response Compensation (ERC) Percentage

Word

Description

INC05

Minimum Velocity Control ERC Percentage [31] Although error coding allows range of 00000 to 09999, the module limits it to a
minimum of 01000.

INC06

Minimum Pressure Control ERC Percentage [31] Although error coding allows range of 00000 to 09999, the module limits it to a
minimum of 01000.

INC07, 08

Open

Unselected Valve Set-output Values

When the module starts the Injection Profile, it:

sets its unselected outputs to the values listed below

ignores the unselected value of the selected output

uses ramp rates INC17 - INC32 to ramp unselected outputs

Word

Description

INC09

Output #1 Set-output Value during Profile [19]

INC10

Output #2 Set-output Value during Profile [19]

INC11

Output #3 Set-output Value during Profile [19]

INC12

Output #4 Set-output Value during Profile [19]

INC13

Output #5 Set-output Value during Profile [19]

INC14

Output #6 Set-output Value during Profile [19]

INC15

Output #7 Set-output Value during Profile [19]

INC16

Output #8 Set-output Value during Profile [19]

Output Ramp Rates

The module uses the following ramp rates when moving its outputs
from setpoint to setpoint during the Injection Profile. The module
interprets a ramp rate of zero as a step function ramp (ramp disable).