2–15

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

DYC

Word

Bit

Description

DYC02

B00

If clamp position exceeds CPC61

and all within any box are true:

then the module:

– CPC11 is zero or is not zero when clamp position is less than all

non-zero entries in CPC11, CPC14, and CPC17

– CPC03-B08 is RESET
– CPC20 is zero or is not zero when clamp position is less than

all non-zero entries in CPC20, CPC23, and CPC26

– CPC03-B09 is RESET
– CPC29 is zero or is not zero when clamp position is less than all

non-zero entries in CPC29, CPC32, and CPC35

– CPC03-B10 is RESET
Also occurs when clamp position exceeds CPC62 but not CPC61

terminates any action in progress, and
starts Low Pressure Close Profile

B01

= 0 Normal
= 1 Execute Second Clamp Close Profile
A false-to-true transition of this bit forces the module to do

one of the following, attempted in the order listed.

if:

then the module:

any of SYS07-B00 through B05 are SET

ignores any profile commands

ejector position exceeds EPC63

latches alarm status bit SYS14-B08

either of the following are true:
– CPC03-B09 is SET and SYS15-B03 is RESET
– SYS15-B06 is RESET

latches SYS13-B02

If clamp position exceeds CPC61

and all within any box are true:

then the module:

– CPC20 is not zero
– clamp position exceeds a non-zero entry in CPC20, CPC23, or CPC26

terminates any action in progress and
starts Second Clamp Close Profile (see note)

– CPC20 is zero or is not zero when clamp position is less than all

non-zero entries in CPC20, CPC23, and CPC26

– CPC03-B09 is SET

terminates any action in progress and
sets outputs to SCC33 - SCC40 (see note)

– CPC20 is zero or is not zero when clamp position is less than all

non-zero entries in CPC20, CPC23, and CPC26

– CPC03-B09 is RESET
– CPC29 is not zero
– clamp position exceeds a non-zero entry in CPC29, CPC32, or CPC35

terminates any action in progress and
starts Third Clamp Close Profile (see note)

– CPC20 is zero or is not zero when clamp position is less than all

non-zero entries in CPC20, CPC23, and CPC26

– CPC03-B09 is RESET
– CPC29 is zero or is not zero when clamp position is less than all

non-zero entries in CPC29, CPC32, and CPC35

– CPC03-B10 is SET

terminates any action in progress and
sets outputs to TCC33 - TCC40 (see note)

– CPC20 is zero or is not zero when clamp position is less than all

non-zero entries in CPC20, CPC23, and CPC26

– CPC03-B09 is RESET
– CPC29 is zero or is not zero when clamp position is less than all

non-zero entries in CPC29, CPC32, and CPC35

– CPC03-B10 is RESET
Also occurs when clamp position exceeds CPC62 but not CPC61.

terminates any action in progress and
starts Low Pressure Clamp Close Profile
(see note)

clamp position equals or is less than CPC62

terminates any action in progress and
sets outputs to LPC33 - LPC40 (see note)

Note: If ejector position exceeds EPC63, the module ceases all action execution,

sets its outputs to zero, and sets alarm status bit SYS14-B08.

B02

= 0 Normal
= 1 Execute Third Clamp Close Profile
A false-to-true transition of this bit forces the module to do

one of the following, attempted in the order listed.

if:

then the module:

any of SYS07-B00 through B05 are SET

ignores any profile commands

ejector position exceeds EPC63

latches alarm status bit SYS14-B08

either of the following are true:
– CPC03-B10 is SET and SYS15-B04 is RESET
– SYS15-B06 is RESET

latches SYS13-B03