Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 194

Advertising
background image

3–18

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

Bit

B07

Segment 8 (Third Clamp Open)

B08

Segment 9 (Third Clamp Open)

B09

Segment 1 (Clamp Open Slow)

B10

Segment 2 (Clamp Open Slow)

B11-B15

Open

First Clamp Open Profile Actuals

Word

Description

OPS09

Actual Segment 1 Velocity [07] or [08] Average clamp velocity during last Segment 1.
If OPC03-B14 is RESET, the module reports this average in percent velocity.
If OPC03-B14 is SET, it reports it in in.(mm)/s.

OPS10

Actual Segment 1 Pressure [02] Average clamp pressure during last Segment 1.

OPS11

Actual Segment 1 Execution Time [21] Time required for last Segment 1.

OPS12

Actual Segment 2 Velocity [07] or [08] Average clamp velocity during last Segment 2.
If OPC03-B14 is RESET, the module reports this average in percent velocity.
If OPC03-B14 is SET, it reports it in in.(mm)/s.

OPS13

Actual Segment 2 Pressure [02] Average clamp pressure during last Segment 2.

OPS14

Actual Segment 2 Execution Time [21] Time required for last Segment 2.

OPS15

Actual Segment 3 Velocity [07] or [08] Average clamp velocity during last Segment 3.
If OPC03-B14 is RESET, the module reports this average in percent velocity.
If OPC03-B14 is SET, it reports it in in.(mm)/s.

OPS16

Actual Segment 3 Pressure [02] Average clamp pressure during last Segment 3.

OPS17

Actual Segment 3 Execution Time [21] Time required for last Segment 3.

Second Clamp Open Profile Actuals

Word

Description

OPS18

Actual Segment 4 Velocity [07] or [08] Average clamp velocity during last Segment 4.
If OPC03-B14 is RESET, the module reports this average in percent velocity.
If OPC03-B14 is SET, it reports it in in.(mm)/s.

OPS19

Actual Segment 4 Pressure [02] Average clamp pressure during last Segment 4.

OPS20

Actual Segment 4 Execution Time [21] Time required for last Segment 4.

OPS21

Actual Segment 5 Velocity [07] or [08] Average clamp velocity during last Segment 5.
If OPC03-B14 is RESET, the module reports this average in percent velocity.
If OPC03-B14 is SET, it reports it in in.(mm)/s.

OPS22

Actual Segment 5 Pressure [02] Average clamp pressure during last Segment 5.

OPS23

Actual Segment 5 Execution Time [21] Time required for last Segment 5

OPS24

Actual Segment 6 Velocity [07] or [08] Average clamp velocity during last Segment 6.
If OPC03-B14 is RESET, the module reports this average in percent velocity.
If OPC03-B14 is SET, it reports it in in.(mm)/s.

OPS25

Actual Segment 6 Pressure [02] Average clamp pressure during last Segment 6.

OPS26

Actual Segment 6 Execution Time [21] Time required for last Segment 6.

Advertising