Psc - post-decompression configuration block, Psc – post-decompression configuration block – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 159

Advertising
background image

2–93

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

PSC

Word

Description

PRC37

Output #5 Set-output Value at End of Movement [19]

PRC38

Output #6 Set-output Value at End of Movement [19]

PRC39

Output #7 Set-output Value at End of Movement [19]

PRC40

Output #8 Set-output Value at End of Movement [19]

PRC41 - 56

Open

Movement Pressure Alarm Setpoint

Word

Description

PRC57

Movement High Pressure Alarm Setpoint [01] The module compares real-time ram (screw) pressure against this entry during the
Pre-decompression Movement. The module sets alarm status bit SYS06-B06 when ram (screw) pressure equals or exceeds this
entry during the Pre- decompression Movement. A zero entry inhibits SYS06-B06.

PRC58 - 64

Open

Bit-mapped Control Words

Word

Bit

Description

PSC01

Block ID = 00010000 (Low byte). High byte reserved for the module. Do not use.

PSC02 - 04

Open

Movement Length

Word

Description

PSC05

Incremental Movement Length [17] When the module starts the Post-decompression Movement, it adds this entry to the sum of
cushion size (PPC61) + shot size (PPC62) to establish the End of Post-decompression ram (screw) position. The module uses End
of Post-decompression position as termination point of all Post-decompression Movements.

PSC06 - 07

Open

Watchdog Timer

Word

Description

PSC08

Movement Watchdog Timer Preset [21] When the module starts the Post-decompression Movement, it:

S

starts an internal Movement Watchdog timer

S

stops this timer and resets its accumulated value to zero (after reporting total execution time in PPS58) when it completes the

movement

S

sets master status bit SYS04-B09 when the accumulated value of this timer equals or exceeds this entry.

A zero entry inhibits SYS04-B09.

Movement Set-output Values

When the module starts the Post-decompression Movement, it:

sets its outputs to the values listed below

uses ramp rates PRC17 - PRC32 to ramp outputs

Word

Description

PSC09

Output #1 Set-output Value during Movement [19]

PSC10

Output #2 Set-output Value during Movement [19]

PSC11

Output #3 Set-output Value during Movement [19]

PSC12

Output #4 Set-output Value during Movement [19]

PSC – Post-decompression
Configuration Block

Advertising