Cps - clamp close profiles status block, Cps – clamp close profiles status block – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 182

Advertising
background image

3–6

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

CLS37

Ejector Tip Advance Segment

CLS38

Reserved

CLS39

Ejector Full Retract Segment 1

CLS40

Ejector Full Retract Segment 2

CLS41

Ejector Full Retract Segment 3

CLS42

Reserved

CLS43 - 64

Open

Bit-mapped Status Words

Word

Bit

Description

CPS01

Block ID = 00000010 (Low byte). High byte identical to SYS01

CPS02

See SYS02

CPS03

See SYS03

CPS04

See SYS04

CPS05

Open

CPS06

Open

CPS07

CV High Limit Alarms

The module latches each bit when executing the subject profile segment in closed loop, and drives its algorithm CV to
maximum (100%) in an attempt to control the profile setpoint.
The module unlatches each bit when it completes execution of the subject profile segment in open loop, or in closed
loop without driving its algorithm CV to maximum (100%).

When this bit
is latched ON:

algorithm CV
is maximum during:

B00

Segment 1 (First Clamp Close)

B01

Segment 2 (First Clamp Close)

B02

Segment 3 (First Clamp Close)

B03

Segment 4 (Second Clamp Close)

B04

Segment 5 (Second Clamp Close)

B05

Segment 6 (Second Clamp Close)

B06

Segment 7 (Third Clamp Close)

B07

Segment 8 (Third Clamp Close)

B08

Segment 9 (Third Clamp Close)

B09

Segment 1 (Clamp Low Pressure Close)

B10

Segment 2 (Clamp Low Pressure Close)

B11-B15

Open

CPS08

CV Low Limit Alarms

The module latches each bit when executing the subject profile segment in closed loop, and drives its algorithm CV to
minimum (0%) in an attempt to control the profile setpoint.
The module unlatches each bit when it completes execution of the subject profile segment in open loop, or in closed
loop without driving its algorithm CV to minimum (0%).

When this bit
is latched ON:

algorithm CV
is maximum during:

B00

Segment 1 (First Clamp Close)

B01

Segment 2 (First Clamp Close)

B02

Segment 3 (First Clamp Close)

B03

Segment 4 (Second Clamp Close)

CPS – Clamp Close
Profiles Status Block

Advertising