Inc - injection configuration block, Inc – injection configuration block – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 119

Advertising
background image

2–53

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

INC

Word

Description

HPC37

Hold Segment 4 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC35 or HPC36 for this
time period beginning at completion of Segment 3.

HPC38

Hold Segment 5 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure to
this setpoint at completion of segment 4 for time period specified by HPC40.

HPC39

Hold Segment 5 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 4 for time period specified by HPC40.

HPC40

Hold Segment 5 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC38 or HPC39 for this
time period beginning at completion of Segment 4.

Hold Profile Offsets

Word

Description

HPC41

Hold Profile Cavity Pressure Offset [04] If you select Cav Press/Time profile execution, the module applies this entry (after reading
the sign bit) to each cavity pressure profile setpoint.

HPC42

Hold Profile Ram (Screw) Pressure Offset [01] If you select Ram Press/Time profile execution, the module applies this entry (after
reading the sign bit) to each ram (screw) pressure profile setpoint.

HPC43 - 60

Open

Critical Process Setpoints

Word

Description

HPC61

Cure Timer Preset [22]
At completion of the Hold Profile, the module:

S

starts an internal Cure Timer

S

sets master status bit SYS03-B03

S

reports the accumulated time in SYS58

When the Cure Timer accumulated value in SYS58 equals this entry, the module:

S

resets master status bit SYS03-B03

S

sets master status bit SYS03-B05

S

stops accumulating time in SYS58

If it receives an F-to-T transition of DYC02-B00, -B01, -B02, -B03 or DYC03-B01, the module:

S

resets master status bit SYS03-B03

S

resets master status bit SYS03-B05

S

resets SYS58 to zero

HPC62 - 64

Open

Bit-mapped Control Words

Word

Bit

Description

INC01

Block ID = 00001000 (Low byte). High byte reserved for the module. Do not use.

INC02

Configuration Selections

B00-B02

Selected Velocity Control Valve
The module uses its algorithm to drive the following output during any Vel/Pos or LimVel/Pos Injection Profile.
B02 B01 B00
0 0 0 Output #1
0 0 1 Output #2
0 1 0 Output #3
0 1 1 Output #4
1 0 0 Output #5
1 0 1 Output #6
1 1 0 Output #7
1 1 1 Output #8

INC02

B03

Open

INC – Injection
Configuration Block

Advertising