Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 211

Advertising
background image

3–35

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

SYS

Word

Bit

Description

B02

Clamp Overtravel on Close

B03

Clamp Overtravel on Open

When this bit
is latched ON:

the module detected this alarm:

B04

Ejector Overtravel on Retract

B05

Ejector Overtravel on Advance

B06

Clamp Close Profile Overtravel into Mold Protection Zone

B07

Clamp Open Profile Overtravel into Open Slow Zone

B08-B15

Reserved for the module. Do not use.

SYS12

Alarm Status for Loss of Input Sensor (Latched)

The module latches alarm bits on each false-to-true transition of the corresponding real-time alarm bit in SYS08. The
module unlatches all 16 bits when it receives a false-to-true transition of DYC03-B09.

When this bit
is latched ON,

the module detected this alarm

B00

Loss of Ram (Screw) Position Sensor (except when MCC64 is SET)

B01

Loss of Ram (Screw) Pressure Sensor (except when MCC64 is SET)

B02

Loss of Clamp Position Sensor (except when MCC64 is SET)

B03

Loss of Clamp Pressure Sensor (except when MCC64 is SET)

B04

Loss of Ejector Position Sensor (except when MCC64 is SET)

B05

Loss of Ejector Pressure Sensor (except when MCC64 is SET)

B06

Loss of Screw RPM Sensor (except when MCC64 is SET)

B07

Loss of Cavity Pressure Sensor (except when MCC64 is SET)

B08-B15

Open

SYS13

Action-execution Command Errors

B00

= 0 Normal
= 1 Jog Command Error
The module latches this bit when SYS15-B01 is RESET and one of the following is true:

S

DYC01-B09 is SET

S

DYC01-B10 is SET

S

DYC01-B11 is SET

DYC01 B12 i SET

C0

S

S

DYC01-B12 is SET

S

DYC01-B13 is SET

S

DYC01-B14 is SET

S

DYC01-B15 is SET

The module unlatches this bit when it decodes a valid DYC Block with any SET action execution bit other than the ones
listed above.

B01

= 0 Normal
= 1 First Clamp Close Profile Command Error
The module latches this bit when all of the following are true:

S

DYC02-B00 is SET

S

CPC03-B08 is SET

S

SYS15-B02 is RESET

The module also latches this bit when both of the following are true:

S

DYC02-B00 is SET

S

SYS15-B06 is RESET

Module unlatches this bit when it decodes a valid DYC Block with any SET action execution bit other than DYC02-B00.

Advertising