Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 147

Advertising
background image

2–81

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

OSC

End of Profile Set-output Values

When the module completes the Clamp Open Slow Profile and
SYS21-B14 is RESET, it:

sets its outputs to the values listed below

sets status bit SYS22-B13

ignores SYS22 and these values and gives output control to the
Ejector Profile if SYS21-B14 is SET

uses ramp rates OSC17 - 32 when changing outputs to these values

Use these values for pulling cores if applied before starting the
Ejector Profile.

Word

Description

OSC33

Output #1 Set-output Value at End of Profile [19]

OSC34

Output #2 Set-output Value at End of Profile [19]

OSC35

Output #3 Set-output Value at End of Profile [19]

OSC36

Output #4 Set-output Value at End of Profile [19]

OSC37

Output #5 Set-output Value at End of Profile [19]

OSC38

Output #6 Set-output Value at End of Profile [19]

OSC39

Output #7 Set-output Value at End of Profile [19]

OSC40

Output #8 Set-output Value at End of Profile [19]

Pressure Control Limits

Word

Description

OSC41

Pressure Minimum Control Limit [02] Minimum controllable clamp pressure attainable during any Press/Pos Clamp Open Slow Pro-
file. The module expects this clamp pressure when setting its selected pressure valve to the %-output in OSC43.

OSC42

Pressure Maximum Control Limit [02] Maximum controllable clamp pressure attainable during any Press/Pos Clamp Open Slow
Profile. The module expects this clamp pressure when setting its selected pressure valve to the %-output in OSC44.

OSC43

Selected Pressure Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected pressure
valve during any Press/Pos Clamp Open Slow Profile. The module expects a pressure equal to OSC41 when setting the selected
pressure valve to this %-output during profile execution. The Press/Pos Clamp Open Slow Profile will be executed as a reverse-act-
ing algorithm if this entry is greater than OSC44.

OSC44

Selected Pressure Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected pressure
valve during any Press/Pos Clamp Open Slow Profile. The module expects a pressure equal to OSC42 when setting the selected
pressure valve to this %-output during profile execution. The Press/Pos Clamp Open Slow Profile will be executed as a reverse-act-
ing algorithm if this entry is less than OSC43.

Velocity Control Limits

Word

Description

OSC45

Velocity Minimum Control Limit [08] Minimum controllable clamp velocity attainable during any Vel/Pos Clamp Open Slow Profile.
The module expects this clamp velocity when setting its selected velocity valve to the %-output in OSC47.

OSC46

Velocity Maximum Control Limit [08] Maximum controllable clamp velocity attainable during any Vel/Pos Clamp Open Slow Profile.
The module expects this clamp velocity when setting its selected velocity valve to the %-output in OSC48.

OSC47

Selected Velocity Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected velocity valve
during any Vel/Pos Clamp Open Slow Profile. The module expects a velocity equal to OSC45 when setting the selected velocity
valve to this %-output during profile execution. The Vel/Pos Clamp Open Slow Profile will be executed as a reverse-acting algorithm
if this entry is greater than OSC48.

OSC48

Selected Velocity Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected velocity
valve during any Vel/Pos Clamp Open Slow Profile. The module expects a velocity equal to OSC46 when setting the selected veloc-
ity valve to this %-output during profile execution. The Vel/Pos Clamp Open Slow Profile will be executed as a reverse-acting algo-
rithm if this entry is less than OSC47.