Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 222

Advertising
background image

3–46

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

Bit

B15

= 0 Normal
= 1 End of Ejector Retract Set-Output in Progress
The module sets this bit when holding its outputs to ERC33 - ERC40 after completion of an ejector retract stroke.
The module resets this bit when it receives any new action execution command bit, or when commanded to continue
the ejector profile by DYC03-B15 = 1.

SYS23

Double command error. You can determine from DYC01 which bits were set or downloaded at the same time.

SYS24

Double command error. You can determine from DYC02 which bits were set or downloaded at the same time.

Input Level In Engineering Units

The module reports real-time input levels scaled to engineering units.

Word

Description

SYS25

Input #1 [11] or [15]

SYS26

Input #2 [01] or [02] or [03]

SYS27

Input #3 [13] or [25]

SYS28

Input #4 [02] or [04]

SYS29

Input #5 [15]

SYS30

Input #6 [03]

SYS31

Input #7 [25]

SYS32

Input #8 [04]

Input Level, Raw Signal

The module reports real-time signal levels at the input to each A/D
input converter.

Word

Description

SYS33

Input #1 [24]

SYS34

Input #2 [24]

SYS35

Input #3 [24]

SYS36

Input #4 [24]

SYS37

Input #5 [24]

SYS38

Input #6 [24]

SYS39

Input #7 [24]

SYS40

Input #8 [24]

Output Level in Percentage

The module reports real-time output percentage it sends to each D/A
output converter.

Word

Description

SYS41

Output #1 [19]

SYS42

Output #2 [19]

SYS43

Output #3 [19]

SYS44

Output #4 [19]

SYS45

Output #5 [19]

SYS46

Output #6 [19]

SYS47

Output #7 [19]

SYS48

Output #8 [19]

Advertising