Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 160

Advertising
background image

2–94

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

PSC13

Output #5 Set-output Value during Movement [19]

PSC14

Output #6 Set-output Value during Movement [19]

PSC15

Output #7 Set-output Value during Movement [19]

PSC16

Output #8 Set-output Value during Movement [19]

Output Ramp Rates

The module uses the following ramp rates when moving its outputs
between setpoints during Post-decompression Movement. The module
interprets a ramp rate of zero as a step function ramp (ramp disable).

Word

Description

PSC17

Output #1 Acceleration Ramp Rate during Movement [20]

PSC18

Output #2 Acceleration Ramp Rate during Movement [20]

PSC19

Output #3 Acceleration Ramp Rate during Movement [20]

PSC20

Output #4 Acceleration Ramp Rate during Movement [20]

PSC21

Output #5 Acceleration Ramp Rate during Movement [20]

PSC22

Output #6 Acceleration Ramp Rate during Movement [20]

PSC23

Output #7 Acceleration Ramp Rate during Movement [20]

PSC24

Output #8 Acceleration Ramp Rate during Movement [20]

PSC25

Output #1 Deceleration Ramp Rate during Movement [20]

PSC26

Output #2 Deceleration Ramp Rate during Movement [20]

PSC27

Output #3 Deceleration Ramp Rate during Movement [20]

PSC28

Output #4 Deceleration Ramp Rate during Movement [20]

PSC29

Output #5 Deceleration Ramp Rate during Movement [20]

PSC30

Output #6 Deceleration Ramp Rate during Movement [20]

PSC31

Output #7 Deceleration Ramp Rate during Movement [20]

PSC32

Output #8 Deceleration Ramp Rate during Movement [20]

End of Movement Set-output Values

When the module completes the Post-decompression Movement, it:

sets its outputs to the following values

sets status bit SYS22-B09

uses ramp rates PSC17 - 32 when changing outputs to these values

Use these values for-pulling cores if applied before starting the first
clamp open profile.

Word

Description

PSC33

Output #1 Set-output Value at End of Movement [19]

PSC34

Output #2 Set-output Value at End of Movement [19]

PSC35

Output #3 Set-output Value at End of Movement [19]

PSC36

Output #4 Set-output Value at End of Movement [19]

PSC37

Output #5 Set-output Value at End of Movement [19]

PSC38

Output #6 Set-output Value at End of Movement [19]

PSC39

Output #7 Set-output Value at End of Movement [19]

PSC40

Output #8 Set-output Value at End of Movement [19]

PSC41 - 56

Open

Advertising