2–88

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Bit-mapped Control Words

Word

Bit

Description

PPC01

Block ID = 00001111 (Low byte). High byte reserved for the module. Do not use.

PPC02

Open

PPC03

Configuration Selections

B00-B01

Profile Algorithm Selection
B01

B00

0

0

Ram (Screw) Press/Pos

0

1

Ram (Screw) Press/Time

1

0

RPM/Pos

1

1

RPM/Time

B02-B07

Open

B08

Plastication/Post-decompression Logical Bridge Selection End of Plastication Profile
= 0 Start Post-decompression Movement at End of Plastication Profile
= 1 Stop and Set-output at End of Plastication Profile
Module checks the state of this pause bit at completion of Plastication Profile to determine what further action to take:
if:

then the module:

SET

sets its outputs to PLC33 - PLC40

RESET, SYS15-B15 = 1,

immediately begins the Post-decompression Movement

and PSC05 > 00000

RESET, SYS15-B15 = 1,

sets its outputs to PSC33 - PSC40

and PRC05 = 00000

RESET and SYS15-B12 = 0

sets its outputs to zero and latches SYS13-B10

B09-B11

Open

Profile Offset Sign Selection

B12

= 0 Plastication RPM Profile Offset is Positive
= 1 Plastication RPM Profile Offset is Negative

B13

= 0 Plastication Pressure Profile Offset is Positive
= 1 Plastication Pressure Profile Offset is Negative

B14-B15

Open

PPC04

Configuration Selections

Open/Closed Loop Selection

B00

= 0 Press/Pos Plastication Profiles Closed Loop
= 1 Press/Pos Plastication Profiles Open Loop

B01

= 0 Press/Time Plastication Profiles Closed Loop
= 1 Press/Time Plastication Profiles Open Loop

B02

= 0 RPM/Pos Plastication Profiles Closed Loop
= 1 RPM/Pos Plastication Profiles Open Loop

B03

= 0 RPM/Time Plastication Profiles Closed Loop
= 1 RPM/Time Plastication Profiles Open Loop

B04-B07

Open

ERC Enabled/Disabled Selection

B08

= 0 Press/Pos Plastication ERC On
= 1 Press/Pos Plastication ERC Off

B09

= 0 Press/Time Plastication ERC On
= 1 Press/Time Plastication ERC Off

B10

= 0 RPM/Pos Plastication ERC On
= 1 RPM/Pos Plastication ERC Off

B11

= 0 RPM/Time Plastication ERC On
= 1 RPM/Time Plastication ERC Off

B12-B15

Open

PPC05 - 08