Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 260

Advertising
background image

4–36

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 15

0461

PPC61 is out of range.
if:

then:

MCC13 and MCC14

PPC61 must be within 00000

PPC61

MCC14 – MCC13

are both non-zero

MCC13 is non-zero and

PPC61 must be within 00000

PPC61

MCC10 – MCC13.

MCC14 is zero

MCC13 is zero and

PPC61 must be within 00000

PPC61

MCC14 – MCC09

MCC14 is non-zero .

MCC13 and MCC14

PPC61 must be within 00000

PPC61

MCC10 – MCC09

are both zero

0462

PPC62 is out of range.
if:

then:

MCC13 and MCC14

PPC62 must be within 00000

PPC62

MCC14 – MCC13

are both non-zero

MCC13 is non-zero and

PPC62 must be within 00000

PPC62

MCC10 – MCC13.

MCC14 is zero

MCC13 is zero and

PPC62 must be within 00000

PPC62

MCC14 – MCC09

MCC14 is non-zero

MCC13 and MCC14

PPC62 must be within 00000

PPC62

MCC10 – MCC09

are both zero

0503

You have selected RPM/Pos execution of the Plastication profile by PPC03-B01 = 1 and
PPC03 -B00 = 0, but your bit pattern in MCC02 indicates that the QDC module is not config-
ured for connection of a screw RPM sensor.

0504

You have selected closed-loop Press/Pos execution for the Plastication Profile by PPC04-B00
= 0, but your bit patterns in MCC02 and MCC03 indicate that the QDC module is not con-
nected to a ram (screw) pressure transducer.

0507

You have selected RPM/Time execution of the Plastication profile by PPC03-B01 = 1 and
PPC03-B00 = 1, but your bit pattern in MCC02 indicates that the QDC module is not config-
ured for connection of a screw RPM sensor.

0508

You have selected closed-loop Press/Time execution of the Plastication Profile by PPC04-B01
= 0, but your bit patterns in MCC02 and MCC03 indicate that the QDC module is not con-
nected to a ram (screw) pressure transducer.

0512

You have selected closed-loop RPM/Pos execution of the Plastication profile by PPC04-B02 =
0, but your bit patterns in MCC02 and MCC03 indicate that the QDC module is not connected
to a screw RPM sensor.

0516

You have selected closed-loop RPM/Time execution of the Plastication profile by PPC04-B03
= 0, but your bit patterns in MCC02 and MCc03 indicate that the QDC module is not con-
nected to a screw RPM sensor.

0600

Your entire Plastication Profile Command Block has been rejected because the QDC module
module does not have a valid Plastication Configuration Command Block on-board
(SYS15-B13 = 0).

0711

PPC11 cannot be 00000 when PPC14 > 00000.

0712

PPC12 cannot be 00000 when PPC14 > 00000.

0715

PPC15 cannot be 00000 when PPC18 > 00000.

0716

PPC16 cannot be 00000 when PPC18 > 00000.

0719

PPC19 cannot be 00000 when PPC22 > 00000.

0720

PPC20 cannot be 00000 when PPC22 > 00000.

0723

PPC23 cannot be 00000 when PPC26 > 00000.

0724

PPC24 cannot be 00000 when PPC26 > 00000.

0727

PPC27 cannot be 00000 when PPC30 > 00000.

0728

PPC28 cannot be 00000 when PPC30 > 00000.

0731

PPC31 cannot be 00000 when PPC34 > 00000.

0732

PPC32 cannot be 00000 when PPC34 > 00000.

0735

PPC35 cannot be 00000 when PPC38 > 00000.

Advertising