Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 132

Advertising
background image

2–66

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

LPC09

Output #1 Set-output Value during Profile [19]

LPC10

Output #2 Set-output Value during Profile [19]

LPC11

Output #3 Set-output Value during Profile [19]

LPC12

Output #4 Set-output Value during Profile [19]

LPC13

Output #5 Set-output Value during Profile [19]

LPC14

Output #6 Set-output Value during Profile [19]

LPC15

Output #7 Set-output Value during Profile [19]

LPC16

Output #8 Set-output Value during Profile [19]

Output Ramp Rates

The module uses the following ramp rates when moving its outputs
from setpoint to setpoint during the Clamp Low Pressure Close
Profile. The module interprets a ramp rate entry of zero as a step
function ramp (ramp disable).

Word

Description

LPC17

Output #1 Acceleration Ramp Rate during Profile [20]

LPC18

Output #2 Acceleration Ramp Rate during Profile [20]

LPC19

Output #3 Acceleration Ramp Rate during Profile [20]

LPC20

Output #4 Acceleration Ramp Rate during Profile [20]

LPC21

Output #5 Acceleration Ramp Rate during Profile [20]

LPC22

Output #6 Acceleration Ramp Rate during Profile [20]

LPC23

Output #7 Acceleration Ramp Rate during Profile [20]

LPC24

Output #8 Acceleration Ramp Rate during Profile [20]

LPC25

Output #1 Deceleration Ramp Rate during Profile [20]

LPC26

Output #2 Deceleration Ramp Rate during Profile [20]

LPC27

Output #3 Deceleration Ramp Rate during Profile [20]

LPC28

Output #4 Deceleration Ramp Rate during Profile [20]

LPC29

Output #5 Deceleration Ramp Rate during Profile [20]

LPC30

Output #6 Deceleration Ramp Rate during Profile [20]

LPC31

Output #7 Deceleration Ramp Rate during Profile [20]

LPC32

Output #8 Deceleration Ramp Rate during Profile [20]

End of Profile Set-output Values

When the module completes the Clamp Low Pressure Close Profile, it:

sets its outputs to the following values

sets status bit SYS22-B03

uses ramp rates LPC17 - 32 when changing outputs to these values

Use these values to apply tonnage to the mold before starting the
Injection Profile, or for setting cores if applied before starting the
Injection Profile.