Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 169

Advertising
background image

2–103

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

SOC

End of Profile Set-output Values

When the module completes the Second Clamp Open Profile and
OPC03-B09 is SET and SYS21-B14 is RESET, it:

sets its outputs to the values listed below

sets status bit SYS22-B11

ignores SYS22 and these values and gives output control to the
Ejector Profile if SYS21-B14 is SET

uses ramp rates SOC17 - 32 when changing outputs to these value

Use these values for pulling cores if applied before starting the Third
Clamp Open Profile.

Word

Description

SOC33

Output #1 Set-output Value at End of Profile [19]

SOC34

Output #2 Set-output Value at End of Profile [19]

SOC35

Output #3 Set-output Value at End of Profile [19]

SOC36

Output #4 Set-output Value at End of Profile [19]

SOC37

Output #5 Set-output Value at End of Profile [19]

SOC38

Output #6 Set-output Value at End of Profile [19]

SOC39

Output #7 Set-output Value at End of Profile [19]

SOC40

Output #8 Set-output Value at End of Profile [19]

Pressure Control Limits

Word

Description

SOC41

Pressure Minimum Control Limit [02] Minimum controllable clamp pressure attainable during any Press/Pos Second Clamp Open
Profile. The module expects this clamp pressure when setting its selected pressure valve to the %-output in SOC43.

SOC42

Pressure Maximum Control Limit [02] Maximum controllable clamp pressure attainable during any Press/Pos Second Clamp Open
Profile. The module expects this clamp pressure when setting its selected pressure valve to the %-output in SOC44.

SOC43

Selected Pressure Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected pressure
valve during any Press/Pos Second Clamp Open Profile. The module expects a pressure equal to SOC41 when setting the selected
pressure valve to this %-output during profile execution. The Press/Pos Second Clamp Open Profile will be executed as a reverse-
acting algorithm if this entry is greater than SOC44.

SOC44

Selected Pressure Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected pressure
valve during any Press/Pos Second Clamp Open Profile. The module expects a pressure equal to SOC42 when setting the selected
pressure valve to this %-output during profile execution. The Press/Pos Second Clamp Open Profile will be executed as a reverse-
acting algorithm if this entry is less than SOC43.

Velocity Control Limits

Word

Description

SOC45

Velocity Minimum Control Limit [08] Minimum controllable clamp velocity attainable during any Vel/Pos Second Clamp Open Profile.
The module expects this clamp velocity when setting its selected velocity valve to the %-output in SOC47.

SOC46

Velocity Maximum Control Limit [08] Maximum controllable clamp velocity attainable during any Vel/Pos Second Clamp Open Profi-
le. The module expects this clamp velocity when setting its selected velocity valve to the %-output in SOC48.

SOC47

Selected Velocity Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected velocity valve
during any Vel/Pos Second Clamp Open Profile. The module expects a velocity equal to SOC45 when setting the selected velocity
valve to this %-output during profile execution. The Vel/Pos Second Clamp Open Profile will be executed as a reverse-acting algo-
rithm if this entry is greater than SOC48.

SOC48

Selected Velocity Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected velocity
valve during any Vel/Pos Second Clamp Open Profile. The module expects a velocity equal to SOC46 when setting the selected
velocity valve to this %-output during profile execution. The Vel/Pos Second Clamp Open Profile will be executed as a reverse-act-
ing algorithm if this entry is less than SOC47.