Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 269

Advertising
background image

4–45

Programming Error Codes

Publication 1771-6.5.88 – July 1997

Error Code

Description

ID = 21

0230

OPC30 is out of range.
When OPC03-B14 = 0, OPC30 must be within 00000

OPC30

09999

0233

OPC33 is out of range.
When OPC03-B14 = 0, OPC33 must be within 00000

OPC33

09999

0236

OPC36 is out of range.
When OPC03-B14 = 0, OPC36 must be within 00000

OPC36

09999

0239

OPC39 is out of range.
When OPC03-B14 = 0, OPC39 must be within 00000

OPC39

09999

0263

OPC63 is out of range. Valid range is 00000

OPC63

09999

0409

OPC09 is out of range.
When OPC03-B14 = 0, OPC39 must be within 00000

OPC39

09999

When OPC03-B14 = 1, a non-zero entry for OPC09 must be within FOC45

OPC09

FOC46

0410

OPC10 is out of range.
If non-zero, OPC10 must be within FOC41

OPC10

FOC42

0411

OPC11 is out of range.
if:

then:

MCC27 and MCC28

OPC11 must be within 00000

OPC11

MCC28 – MCC27

are both non-zero

MCC27 is non-zero and

OPC11 must be within 00000

OPC11

MCC24 – MCC27.

MCC28 is zero

MCC27 is zero and

OPC11 must be within 00000

OPC11

MCC28 – MCC23.

MCC28 is non-zero

MCC27 and MCC28

OPC11 must be within 00000

OPC11

MCC24 – MCC23

are both zero

0412

OPC12 is out of range. When OPC03-B14 = 1, a non-zero entry for OPC12 must be within
FOC45

OPC12

FOC46

0413

OPC13 is out of range.
If non-zero, OPC13 must be within FOC41

OPC13

FOC42

0414

OPC14 is out of range.
if:

then:

MCC27 and MCC28

OPC14 must be within 00000

OPC14

MCC28 – MCC27

are both non-zero

MCC27 is non-zero and

OPC14 must be within 00000

OPC14

MCC24 – MCC27.

MCC28 is zero

MCC27 is zero and

OPC14 must be within 00000

OPC14

MCC28 – MCC23

MCC28 is non-zero

MCC27 and MCC28

OPC14 must be within 00000

OPC14

MCC24 – MCC23

are both zero

0415

OPC15 is out of range. When OPC03-B14 = 1, a non-zero entry for OPC15 must be within
FOC45

OPC15

FOC46

0416

OPC16 is out of range.
If non-zero, OPC16 must be within FOC41

OPC16

FOC42

0417

OPC17 is out of range.
if:

then:

MCC27 and MCC28

OPC17 must be within 00000

OPC17

MCC28 – MCC27

are both non-zero

MCC27 is non-zero and

OPC17 must be within 00000

OPC17

MCC24 – MCC27.

MCC28 is zero

MCC27 is zero and

OPC17 must be within 00000

OPC17

MCC28 – MCC23

MCC28 is non-zero

If MCC27 and MCC28

OPC17 must be within 00000

OPC17

MCC24 – MCC23

are both zero

0418

OPC18 is out of range. When OPC03-B14 = 1, a non-zero entry for OPC18 must be within
SOC45

OPC18

SOC46