Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 202

Advertising
background image

3–26

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

Bit

SYS02

Profile Execution Status
The module sets each bit, SYS02 - B00 through B14 when:

S

it completes the profile or movement, or

S

it receives a new action execution command that terminates the profile or movement

The module resets each bit, SYS02 - B00 through B14 when:

S

it starts the profile or movement, or

S

it receives a valid DYC with DYC03-B10 SET

B00

= 0 Normal
= 1 First Clamp Close Profile Complete

B01

= 0 Normal
= 1 Second Clamp Close Profile Complete

B02

= 0 Normal
= 1 Third Clamp Close Profile Complete

B03

= 0 Normal
= 1 Clamp Low Pressure Close Profile Complete

B04

= 0 Normal
= 1 Injection Profile Complete

B05

= 0 Normal
= 1 Pack Profile Complete

B06

= 0 Normal
= 1 Hold Profile Complete

B07

= 0 Normal
= 1 Pre-decompression Movement Complete

B08

= 0 Normal
= 1 Plastication Profile Complete

B09

= 0 Normal
= 1 Post-decompression Movement Complete

B10

= 0 Normal
= 1 First Clamp Open Profile Complete

B11

= 0 Normal
= 1 Second Clamp Open Profile Complete

B12

= 0 Normal
= 1 Third Clamp Open Profile Complete

B13

= 0 Normal
= 1 Clamp Open Slow Profile Complete

B14

= 0 Normal
= 1 Ejector Profile Complete

Module Busy Status

B15

= 0 Normal
= 1 No Action in Progress
The module resets this bit when it is performing one of the following:

S

executing a profile or decompression movement

S

holding its outputs at any End of phase values

S

executing any jog movement

Advertising