Hps - pack/hold profile status block, Hps – pack/hold profile status block – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 187

Advertising
background image

3–11

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

HPS

Ejector Profile Maximum Pressure

Word

Description

EPS53

Maximum Pressure During Ejector Profile [03] Maximum instantaneous ejector pressure during last profile.

EPS54 - 56 Open

Ejector Profile Execution Time

Word

Description

EPS57

Ejector Profile Execution Time [21] Total time required for last profile.

EPS58 - 64 Open

Bit-mapped Status Words

Word

Bit

Description

HPS01

Block ID = 00000100 (Low byte). High byte identical to SYS01

HPS02

See SYS02

HPS03

See SYS03

HPS04

See SYS04

HPS05

Open

HPS06

Open

HPS07

CV High Limit Alarms

For Pack Phase

The module latches each bit when executing the subject profile segment in closed loop, and drives its algorithm CV to
maximum (100%) in an attempt to control the profile setpoint.
The module unlatches each bit when it completes execution of the subject profile segment in open loop, or in closed
loop without driving its algorithm CV to maximum (100%).

When this bit
is latched ON:

algorithm CV
is maximum during:

B00

Pack Segment 1

B01

Pack Segment 2

B02

Pack Segment 3

B03

Pack Segment 4

B04

Pack Segment 5

B05-B07

Open

For Hold Phase

The module latches each bit when executing the subject profile segment in closed loop, and drives its algorithm CV to
maximum (100%) in an attempt to control the profile setpoint.
The module unlatches each bit when it completes execution of the subject profile segment in open loop, or in closed
loop without driving its algorithm CV to maximum (100%).

When this bit
is latched ON:

algorithm CV
is maximum during:

B08

Hold Segment 1

B09

Hold Segment 2

B10

Hold Segment 3

B11

Hold Segment 4

B12

Hold Segment 5

B13-B15

Open

HPS – Pack/Hold Profile
Status Block

Advertising