1–9

Abbreviated Command and Status Blocks

Publication 1771-6.5.88 – July 1997

Set-output Values for Unselected Valves (During Profile)

FCC09

N43:5

Output #1

FCC10

N43:6

Output #2

FCC11

N43:7

Output #3

FCC12

N43:8

Output #4

FCC13

N43:9

Output #5

FCC14

N43:10

Output #6

FCC15

N43:11

Output #7

FCC16

N43:12

Output #8

Acceleration Ramp Rates

FCC17

N43:13

Output #1

FCC18

N43:14

Output #2

FCC19

N43:15

Output #3

FCC20

N43:16

Output #4

FCC21

N43:17

Output #5

FCC22

N43:18

Output #6

FCC23

N43:19

Output #7

FCC24

N43:20

Output #8

Deceleration Ramp Rates

FCC25

N43:21

Output #1

FCC26

N43:22

Output #2

FCC27

N43:23

Output #3

FCC28

N43:24

Output #4

FCC29

N43:25

Output #5

FCC30

N43:26

Output #6

FCC31

N43:27

Output #7

FCC32

N43:28

Output #8

End of Profile Set-output Values

FCC33

N43:29

Output #1

FCC34

N43:30

Output #2

FCC35

N43:31

Output #3

FCC36

N43:32

Output #4

FCC37

N43:33

Output #5

FCC38

N43:34

Output #6

FCC39

N43:35

Output #7

FCC40

N43:36

Output #8

Pressure Control Limits

FCC41

N43:37

Minimum limit

FCC42

N43:38

Maximum limit

FCC43

N43:39

% output for minimum

FCC44

N43:40

% output for maximum

Velocity Control Limits

FCC45

N43:41

Minimum limit

FCC46

N43:42

Maximum limit

FCC47

N43:43

% output for minimum

FCC48

N43:44

% output for maximum

Advertising