Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 27

1–9
Abbreviated Command and Status Blocks
Publication 1771-6.5.88 – July 1997
Set-output Values for Unselected Valves (During Profile)
FCC09
N43:5
Output #1
FCC10
N43:6
Output #2
FCC11
N43:7
Output #3
FCC12
N43:8
Output #4
FCC13
N43:9
Output #5
FCC14
N43:10
Output #6
FCC15
N43:11
Output #7
FCC16
N43:12
Output #8
Acceleration Ramp Rates
FCC17
N43:13
Output #1
FCC18
N43:14
Output #2
FCC19
N43:15
Output #3
FCC20
N43:16
Output #4
FCC21
N43:17
Output #5
FCC22
N43:18
Output #6
FCC23
N43:19
Output #7
FCC24
N43:20
Output #8
Deceleration Ramp Rates
FCC25
N43:21
Output #1
FCC26
N43:22
Output #2
FCC27
N43:23
Output #3
FCC28
N43:24
Output #4
FCC29
N43:25
Output #5
FCC30
N43:26
Output #6
FCC31
N43:27
Output #7
FCC32
N43:28
Output #8
End of Profile Set-output Values
FCC33
N43:29
Output #1
FCC34
N43:30
Output #2
FCC35
N43:31
Output #3
FCC36
N43:32
Output #4
FCC37
N43:33
Output #5
FCC38
N43:34
Output #6
FCC39
N43:35
Output #7
FCC40
N43:36
Output #8
Pressure Control Limits
FCC41
N43:37
Minimum limit
FCC42
N43:38
Maximum limit
FCC43
N43:39
% output for minimum
FCC44
N43:40
% output for maximum
Velocity Control Limits
FCC45
N43:41
Minimum limit
FCC46
N43:42
Maximum limit
FCC47
N43:43
% output for minimum
FCC48
N43:44
% output for maximum