3–36

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Bit

Description

SYS13

B02

= 0 Normal
= 1 Second Clamp Close Profile Command Error
The module latches this bit when both of the following are true:

S

DYC02-B01 is SET

S

SYS15-B06 is RESET

The module unlatches this bit when it decodes a valid Dynamic Command Block with any SET action execution bit
other than DYC02-B01.

B03

= 0 Normal
= 1 Third Clamp Close Profile Command Error
The module latches this bit when both of the following are true:

S

DYC02-B02 is SET

S

SYS15-B06 is RESET

The module unlatches this bit when it decodes a valid Dynamic Command Block with any SET action execution bit
other than DYC02-B02.

B04

= 0 Normal
= 1 Clamp Low Pressure Close Profile Command Error
The module latches this bit when both of the following are true:

S

DYC02-B03 is SET

S

SYS15-B06 is RESET

The module unlatches this bit when it decodes a valid Dynamic Command Block with any SET action execution bit
other than DYC02-B03.

B05

= 0 Normal
= 1 Injection Profile Command Error
The module latches this bit when both of the following are true:

S

DYC02-B04 is SET

S

SYS15-B08 is RESET

The module unlatches this bit when it decodes a valid Dynamic Command Block with any SET action execution bit
other than DYC02-B04.

B06

= 0 Normal
= 1 Pack Profile Command Error
The module latches this bit when both of the following are true:

S

DYC02-B05 is SET

S

the Injection Profile completes

The module unlatches this bit when it decodes a valid Dynamic Command Block with any SET action execution bit
other than DYC02-B05.

B07

= 0 Normal
= 1 Hold Profile Command Error
The module latches this bit when both of the following are true:

S

DYC02-B06 is SET

S

SYS15-B11 is RESET

The module unlatches this bit when it decodes a valid Dynamic Command Block with any SET action execution bit
other than DYC02-B06.

B08

= 0 Normal
= 1 Pre-decompression Movement Command Error
The module latches this bit at completion of the Hold Profile if all of the following are true:

S

HPC03-B08 is RESET

S

HPC03-B09 is SET

S

SYS15-B12 is RESET

The module also latches this bit if all of the following are true:

S

DYC02-B07 is SET

S

HPC03-B09 is SET

S

SYS15-B12 is RESET

The module also latches this bit if both of the following are true:

S

DYC02-B07 is SET

S

SYS15-B11 is RESET

The module also latches this bit if both of the following are true:

S

DYC02-B07 is SET

S

PRC05 added to the actual ram (screw) position equals or exceeds MCC12

Module unlatches this bit when it decodes a valid DYC Block with any SET action execution bit other than DYC02-B07.

Advertising