2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

MCC14

Ram (Screw) Position Maximum Software Travel Limit [11] The module continuously compares real-time ram (screw) position
against this entry. The module sets alarm status bit SYS07-B01 and forces all of its outputs to zero when executing a ram (screw)
reverse profile or movement (Pre-decompression, Plastication, Post-decompression) and ram (screw) position equals or exceeds
this entry. A zero entry inhibits SYS07-B01.

MCC15

Ram (Screw) Software Travel Limit Alarm Deadband [17] After sensing a ram (screw) overtravel and latching alarm status bit
SYS07-B00 or SYS07-B01, the module will not unlatch bit until real-time ram (screw) position is inside the overtravel setpoint by an
incremental length equal to this entry. This incremental position is added to MCC13 in order to determine ram (screw) position re-
quired to unlatch SYS07-B00. This incremental position is subtracted from MCC14 in order to determine ram (screw) position re-
quired to unlatch SYS07-B01.

MCC16

Ram (Screw) Position Transducer Digital Filter [23] A non-zero entry forces the module to filter the input before using the result for
all ram (screw) position calculations. Use this parameter when required to soften the input signal from a linear potentiometer.

Ram (Screw) Pressure Transducer Configuration

The module accesses data in MCC17-MCC22 if bit patterns in
MCC02 and MCC03 indicate that the module is connected to a ram
(screw) pressure sensor.

Word

Description

MCC17

Minimum Ram (Screw) Pressure [01]

MCC18

Maximum Ram (Screw) Pressure [01]

MCC19

Analog Signal at Minimum Ram (Screw) Pressure [24]

MCC20

Analog Signal at Maximum Ram (Screw) Pressure [24]

MCC21

High Ram (Screw) Pressure Alarm Setpoint [01] The module continuously compares real-time ram (screw) pressure against this
entry. The module sets alarm status bit SYS05-B00 when ram (screw) pressure equals or exceeds this entry. A zero entry inhibits
SYS05-B00.

MCC22

Ram (Screw) Pressure Alarm Time Delay [23] Total time the module must monitor a continuous ram (screw) pressure in excess of

h

i

ll

(

)

l

i

b f

i

h

i

d l

bi S

i /bi

i

f

(

)

y [ ]

(

)

the non-zero entry in all ram (screw) pressure alarm setpoints before setting the associated alarm status bit. Setpoint/bit pairs af-
fected are:

fected are:

Setpoint

Alarm Stat s Bit

Setpoint

Alarm Status Bit

MCC21

SYS05-B00

MCC21

SYS05-B00

JGC06

SYS05-B09

INC57

SYS06 B00

INC57

SYS06-B00

PKC57

SYS06-B02

PKC57

SYS06-B02

HDC57

SYS06-B04

HDC57

SYS06-B04

PRC57

SYS06-B06

PLC57

SYS06 B07

PLC57

SYS06-B07

PSC57

SYS06-B08

PSC57

SYS06-B08

Use a non-zero entry to filter out ram (screw) pressure spikes of short enough duration that they should not be considered an alarm

Use a non-zero entry to filter out ram (screw) pressure spikes of short enough duration that they should not be considered an alarm.

Clamp Position Transducer Configuration

The module accesses data in MCC23-MCC30 if bit patterns in
MCC02 and MCC03 indicate that the module is connected to a
clamp position sensor.

Word

Description

MCC23

Minimum Clamp Position [13]

MCC24

Maximum Clamp Position [13]

MCC25

Analog Signal at Minimum Clamp Position [24]

MCC26

Analog Signal at Maximum Clamp Position [24]