3–27

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

SYS

Word

Bit

Description

SYS03

Miscellaneous Status

B00

= 0 Normal
= 1 Clamp in Mold Protection Zone
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a clamp position transducer, the module
sets this bit when clamp position is equal to or less than the Start Clamp Low Pressure Close position (CPC61).

B01

= 0 Normal
= 1 Mold Safe
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a clamp position transducer, the module
sets this bit when clamp position is equal to or less than the Mold Safe position (CPC62).

B02

= 0 Normal
= 1 Tonnage Complete
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a clamp pressure transducer, the module
latches this bit when both of the following are true:

S

clamp pressure equals or exceeds the Tonnage Pressure (CPC63).

S

clamp position equals or is less than the Mold Safe position (CPC62).

The module unlatches this bit when either of the following are true:

S

clamp pressure is less than the Tonnage Pressure (CPC63).

S

clamp position exceeds the Mold Safe position (CPC62).

B03

= 0 Normal
= 1 Cure Timer Timing
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a ram (screw) position transducer, the
module sets this bit when the internal Cure Timer is timing and the accumulated Cure Time (SYS58) is less than the
Cure Timer preset (HPC61).

B04

= 0 Normal
= 1 Ram (Screw) Retracted
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a ram (screw) position transducer, the
module sets this bit when ram (screw) position equals or exceeds the Full Retract position of Cushion + Shot Size +
Post-decompression (PPC61 + PPC62 + PSC05).

B05

= 0 Normal
= 1 Cure Time Complete
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a ram (screw) position transducer, the
module sets this bit when the accumulated value of its internal Cure Timer (SYS58) equals the Cure Timer preset
(HPC61).

B06

= 0 Normal
= 1 Clamp in Open Slow Zone
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a clamp position transducer, the module
sets this bit when clamp position equals or exceeds the Start Clamp Open Slow position (OPC61).

B07

= 0 Normal
= 1 Mold Open
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a clamp position transducer, the module
sets this bit when clamp position equals or exceeds the Mold Open position (OPC62) with hysteresis of 0.05” (0.5mm).

B08

= 0 Normal
= 1 Ejector Profile stopped at End of Stroke.
If bit patterns in MCC02 and MCC03 indicate that the module is connected to a ejector position transducer, the module:
latches this bit if EPC03-B12 is SET and ejector position reaches any of the following:

S

EPC59 during Ejector Profile full-advance stroke

S

EPC23 during Ejector Profile tip-retract stroke

S

EPC29 during Ejector Profile tip-advance stroke

S

EPC60 during Ejector Profile full-retract stroke when the total advance strokes executed during the profile is less than

EPC64

does not latch this bit at completion of final full-retract stroke

unlatches this bit when any one of the following occur:

S

the module decodes a valid DYC having DYC03-B15 SET.

S

the module decodes a valid EPC having EPC03-B12 RESET.

S

Early termination of the Ejector Profile is forced by receipt of a new action execution command bit.