Ops - clamp open profiles status block, Ops – clamp open profiles status block – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual

Page 193

Advertising
background image

3–17

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

OPS

Injection Transition Actuals

Word

Description

IPS61

Actual Time to Transition [21] Total time required for last Injection Profile.

IPS62

Actual Ram (Screw) Position at Transition [12] Instantaneous ram (screw) position at completion of last Injection Profile.

IPS63

Actual Ram (Screw) Pressure at Transition [01] Instantaneous ram (screw) pressure at completion of last Injection Profile.

IPS64

Actual Cavity Pressure at Transition [04] Instantaneous cavity pressure at completion of last Injection Profile.

Bit-mapped Status Words

Word

Bit

Description

OPS01

Block ID = 00000110 (Low byte). High byte identical to SYS01.

OPS02

See SYS02

OPS03

See SYS03

OPS04

See SYS04

OPS05

Open

OPS06

Open

OPS07

CV High Limit Alarms

The module latches each bit when executing the subject profile segment in closed loop, and drives its algorithm CV to
maximum (100%) in an attempt to control the profile setpoint.
The module unlatches each bit when it completes execution of the subject profile segment in open loop, or in closed
loop without driving its algorithm CV to maximum (100%).

When this bit
is latched ON:

algorithm CV
is maximum during:

B00

Segment 1 (First Clamp Open)

B01

Segment 2 (First Clamp Open)

B02

Segment 3 (First Clamp Open)

B03

Segment 4 (Second Clamp Open)

B04

Segment 5 (Second Clamp Open)

B05

Segment 6 (Second Clamp Open)

B06

Segment 7 (Third Clamp Open)

B07

Segment 8 (Third Clamp Open)

B08

Segment 9 (Third Clamp Open)

B09

Segment 1 (Clamp Open Slow)

B10

Segment 2 (Clamp Open Slow)

B11-B15

Open

OPS08

CV Low Limit Alarms

The module latches each bit when executing the subject profile segment in closed loop, and drives its algorithm CV to
minimum (0%) in an attempt to control the profile setpoint.
The module unlatches each bit when it completes execution of the subject profile segment in open loop, or in closed
loop without driving its algorithm CV to minimum (0%).

When this bit
is latched ON:

algorithm CV
is minimum during:

B00

Segment 1 (First Clamp Open)

B01

Segment 2 (First Clamp Open)

B02

Segment 3 (First Clamp Open)

B03

Segment 4 (Second Clamp Open)

B04

Segment 5 (Second Clamp Open)

B05

Segment 6 (Second Clamp Open)

B06

Segment 7 (Third Clamp Open)

OPS – Clamp Open