3–37

Status Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

SYS

Word

Bit

Description

B09

= 0 Normal
= 1 Plastication Profile Command Error
The module latches this bit at completion of the Hold Profile if all of the following are true:

S

HPC03-B08 is RESET

S

SYS15-B12 is RESET

S

HPC03-B09 is RESET

S

SYS15-B14 is RESET

The module also latches this bit at completion of the Pre-decompression Movement if both of the following are true:

S

HPC03-B09 is RESET

S

SYS15-B14 is RESET

The module also latches this bit if all of the following are true:

S

DYC02-B07 is RESET

S

PRC05 equal zero

S

HPC03-B09 is RESET

S

SYS15-B14 is RESET

The module also latches this bit if all of the following are true:

S

DYC02-B07 is RESET

S

SYS15-B12 is RESET

S

HPC03-B09 is RESET

S

SYS15-B14 is RESET

The module also latches this bit if both of the following are true:

S

DYC02-B08 is SET

S

SYS15-B14 is RESET

The module unlatches this bit when it decodes a valid DYC Block with any SET action execution bit other than
DYC02-B07 or DYC02-B08.

B10

= 0 Normal
= 1 Post-decompression Movement Command Error
The module latches this bit at completion of the Plastication Profile if both of the following are true:

S

PPC03-B08 is RESET

S

SYS15-B15 is RESET

The module also latches this bit if all of the following are true:

S

Ram (screw) position equals or exceeds the sum of PPC61 and PPC62

S

PPC03-B08 is RESET

S

SYS15-B15 is RESET

The module also latches this bit if both of the following are true:

S

DYC02-B09 is SET

S

SYS15-B15 is RESET

The module also latches this bit if both of the following are true:

S

DYC02-B09 is SET

S

PSC05 added to the actual ram (screw) position equals or exceeds MCC12

The module unlatches this bit when it decodes a valid Dynamic Command Block with any SET action execution bit
other than DYC02-B08 or DYC02-B09.

B11

= 0 Normal
= 1 First Clamp Open Profile Command Error
The module latches this bit when all of the following are true:

S

DYC02-B10 is SET

S

OPC03-B08 is SET

S

SYS16-B00 is RESET

The module also latches this bit when both of the following are true:

S

DYC02-B10 is SET

S

SYS16-B04 is RESET

Module unlatches this bit when it decodes a valid DYC Block with any SET action execution bit other than DYC02-B10.